Evidence map›Paper›PMID 37895800›Full record

ArticleMaterials (Basel, Switzerland)2023

Quasi-Static Modelling of a Full-Channel Effective Magnetorheological Damper with Trapezoidal Magnetic Rings.

Huan Wu, Yiming Hu, Yinong Li, Sanbao Gu, Ziyang Yue, Xiaoxue Yang, Ling Zheng

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Huan WuState Key Laboratory of Mechanical Transmission, Chongqing University, Chongqing 400030, China.
Yiming HuSchool of Mechatronics and Vehicle Engineering, East China Jiaotong University, Nanchang 330013, China.
Yinong LiState Key Laboratory of Mechanical Transmission, Chongqing University, Chongqing 400030, China.
Sanbao GuState Key Laboratory of Mechanical Transmission, Chongqing University, Chongqing 400030, China.
Ziyang YueState Key Laboratory of Mechanical Transmission, Chongqing University, Chongqing 400030, China.
Xiaoxue YangState Key Laboratory of Mechanical Transmission, Chongqing University, Chongqing 400030, China.
Ling ZhengState Key Laboratory of Mechanical Transmission, Chongqing University, Chongqing 400030, China.

Funding

National Natural Science Foundation of China Youth Science Foundation NO. 52302470The graduate research and innovation foundation of Chongqing No. CYB21011
6 · The paper itself

Abstract

Magnetorheological damper (MRD) has been successfully applied to vehicle suspension systems as an intelligent core component. Most conventional MRDs have closed rectangle-shaped magnetic circuits, resulting in a short effective working length and negligible damping force. To address the above issues, a novel full-channel effective MRD with trapezoidal magnetic rings (FEMRD_TMR) is proposed. The trapezoidal magnetic ring can shunt the magnetic circuit, distributing it evenly along the damping channel and increasing the effective working length. Additionally, which has the same variation trend as the magnetic flux through it, makes the magnetic induction intensity distribution more uniform to reduce the magnetic saturation problem. Theoretically analyzing the damping characteristics of the FEMRD_TMR, a quasi-static model is developed to forecast the output damping force. The structural design of MRD is challenging since conventional quasi-static models rely on the yield stress of magnetorheological fluid (MRF) to reflect the rheological property, which cannot be directly observed and is challenging to calculate. The Takagi-Sugeno (T-S) fuzzy neural network and a unique magnetic circuit computation are offered as a novel quasi-static modeling approach to address the issue. The MRF's yield stress is linearized into magnetic induction intensity functions by the T-S fuzzy neural network and then converted into the MRD's structural size by the special magnetic circuit calculation. Therefore, the proposed quasi-static model can directly reflect the relationship between the damping force and structure size, simplifying MRD's structure design. The novel quasi-static model is shown to be more straightforward and understandable than the conventional Bingham quasi-static model and to have approximately accurate damping force prediction when compared to experimental data.

Indexed as

full-channel effectivemagnetic circuit designmagnetorheological damperquasi-static modeltrapezoidal magnetic ring

Identifiers

PMID37895800
PMCPMC10608024

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.