Evidence map›Paper›PMID 37895383›Full record

ArticleLife (Basel, Switzerland)2023

Optical and Clinical Outcomes of an Isofocal Intraocular Lens vs. a Monofocal Standard Lens.

Lidia Pérez-Sanz, Veronica Gonzalez-Fernandez, José Antonio Gómez-Pedrero, César Albarrán-Diego, María García-Montero, Nuria Garzón

Abstract read
In one paragraph

Article in Life (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Refining mini-monovision with monofocal plus intraocular lenses.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
    Article
  4. Article
  5. Article
  6. Optical power profiles and aberrations of a non-diffractive wavefront-shaping extended depth of focus intraocular lens.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Lidia Pérez-SanzOptometry and Vision Department, Facultad de Óptica y Optometría, Universidad Complutense de Madrid, C/Arcos de Jalón, 118, 28037 Madrid, Spain.ORCID 0000-0002-9164-9627
Veronica Gonzalez-FernandezOptics Department, Facultad de Óptica y Optometría, Universidad Complutense de Madrid, C/Arcos de Jalón, 118, 28037 Madrid, Spain.ORCID 0000-0001-8153-2903
José Antonio Gómez-PedreroOptics Department, Facultad de Óptica y Optometría, Universidad Complutense de Madrid, C/Arcos de Jalón, 118, 28037 Madrid, Spain.ORCID 0000-0001-7043-3256
César Albarrán-DiegoDepartament d'Òptica i Optometria i Ciències de la Visió, Facultat de Física, Universitat de València, C/Doctor Moliner, 46100 Burjassot, Spain.ORCID 0000-0001-8972-1784
María García-MonteroOptometry and Vision Department, Facultad de Óptica y Optometría, Universidad Complutense de Madrid, C/Arcos de Jalón, 118, 28037 Madrid, Spain.
Nuria GarzónOptometry and Vision Department, Facultad de Óptica y Optometría, Universidad Complutense de Madrid, C/Arcos de Jalón, 118, 28037 Madrid, Spain.

Funding

Agencia Estatal de Investigación PID2021-122486OA-I00
6 · The paper itself

Abstract

The aim of this study is to evaluate the results obtained on the optical bench and clinically with an isofocal lens (ISOPure, BVI medical, Belgium) to compare them to a standard monofocal one (MicroPure, BVI medical, Belgium). To do so, we have combined laboratory investigation and a prospective, comparative, and randomized clinical study. First, we have measured the wavefront of the two models studied using a NIMO TR1504 (Lambda-X, Belgium) deflectometer for three nominal powers: +10.00, +20.00 and +30.00 D. In the randomized study with 48 patients, half of them implanted with ISOPure and the other with MicroPure, we have measured visual acuities and contrast sensitivity under photopic and mesopic conditions. The optical bench results show that the isofocal lens presented higher power than the monofocal one, at the lens center, due to the spherical aberration (coefficients Z(4,0), Z(6,0) and Z(8,0)) induced by the greater asphericity of its design. The addition obtained depended on the nominal power, from +1.00 to +1.50 D. The results of the clinical study showed that the ISOPure lens presented better visual outcomes, which were statistically significant, at intermediate distance compared to the MicroPure lens (

Indexed as

cataractextended depth of focusintraocular lensisofocal

Identifiers

PMID37895383
PMCPMC10608665

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.