Evidence map›Paper›PMID 37893253›Full record

ArticleMicromachines2023

A 0.8 V, 14.76 nVrms, Multiplexer-Based AFE for Wearable Devices Using 45 nm CMOS Techniques.

Esther Tamilarasan, Gracia Nirmala Rani Duraisamy, Muthu Kumaran Elangovan, Arun Samuel Thankmony Sarasam

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Esther TamilarasanDepartment of Electronics and Communication, Thigarajar College of Engineering, Madurai 625005, Tamil Nadu, India.ORCID 0000-0003-0269-4002
Gracia Nirmala Rani DuraisamyDepartment of Electronics and Communication, Thigarajar College of Engineering, Madurai 625005, Tamil Nadu, India.
Muthu Kumaran ElangovanEngineering, D.R.B.R. Ambedkar Institute of Technology, Port Blair 744101, Union Territory of Andaman & Nicobar Islands, India.
Arun Samuel Thankmony SarasamDepartment of Electronics and Communication , National Engineering College, Kovilpatti 628503, Tamil Nadu, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wearable medical devices (WMDs) that continuously monitor health conditions enable people to stay healthy in everyday situations. A wristband is a monitoring format that can measure bioelectric signals. The main part of a wearable device is its analog front end (AFE). Wearables have issues such as low reliability, high power consumption, and large size. A conventional AFE device uses more analog-to-digital converters, amplifiers, and filters for individual electrodes. Our proposed MUX-based AFE design requires fewer components than a conventional AFE device, reducing power consumption and area. It includes a single-ended differential feedback operational transconductance amplifier (OTA) and n-pass MUX-based AFE circuits which are related to the emergence of low power, low area, and low cost AFE-integrated chips that are required for wearable biomedical applications. The proposed 6T n-pass multiplexer measures a gain of -68 dB across a frequency range of 100 kHz with a 136.5 nW power consumption and a delay of 0.07 ns. The design layout area is approximately 9.8 µm

Indexed as

analog front end (AFE)analog multiplexerCadence VirtuosoCMOSoperational transconductance amplifierwearable medical devices (WMD)

Identifiers

PMID37893253
PMCPMC10609258

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.