Evidence map›Paper›PMID 37892936›Full record

ArticleBioengineering (Basel, Switzerland)2023

Automatic Assessment of Transcatheter Aortic Valve Implantation Results on Four-Dimensional Computed Tomography Images Using Artificial Intelligence.

Laura Busto, César Veiga, José A González-Nóvoa, Silvia Campanioni, Pablo Juan-Salvadores, Víctor Alfonso Jiménez Díaz, José Antonio Baz, José Luis Alba-Castro, Maximilian Kütting, Andrés Íñiguez

Open access · goldAbstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.1field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

Laura BustoCardiology Research Group, Galicia Sur Health Research Institute (IIS Galicia Sur), 36312 Vigo, Spain.ORCID 0000-0002-1464-2616
César VeigaCardiology Research Group, Galicia Sur Health Research Institute (IIS Galicia Sur), 36312 Vigo, Spain.ORCID 0000-0003-4165-5049
José A González-NóvoaCardiology Research Group, Galicia Sur Health Research Institute (IIS Galicia Sur), 36312 Vigo, Spain.ORCID 0000-0003-2334-1556
Silvia CampanioniCardiology Research Group, Galicia Sur Health Research Institute (IIS Galicia Sur), 36312 Vigo, Spain.ORCID 0000-0002-9088-1336
Pablo Juan-SalvadoresCardiology Research Group, Galicia Sur Health Research Institute (IIS Galicia Sur), 36312 Vigo, Spain.ORCID 0000-0002-3096-8114
Víctor Alfonso Jiménez DíazCardiology Department, Complexo Hospitalario Universitario de Vigo (SERGAS), Álvaro Cunqueiro Hospital, 36312 Vigo, Spain.ORCID 0000-0002-5271-1993
José Antonio BazCardiology Department, Complexo Hospitalario Universitario de Vigo (SERGAS), Álvaro Cunqueiro Hospital, 36312 Vigo, Spain.
José Luis Alba-CastroatlanTTic Research Center for Telecommunication Technologies, University of Vigo, 36310 Vigo, Spain.ORCID 0000-0001-6319-5915
Maximilian KüttingNew Valve Technology/Biosensors, 72379 Hechingen, Germany.
Andrés ÍñiguezCardiology Department, Complexo Hospitalario Universitario de Vigo (SERGAS), Álvaro Cunqueiro Hospital, 36312 Vigo, Spain.
Galicia Sur Biomedical Foundation · ESUniversity Hospital Complex Of Vigo · ESNew Valve Technology (Germany) · DEUniversidade de Vigo · ES

Funding

Axencia Galega de Innovacion IN607B- 2021/18New Valve Technology (Germany) N/A
6 · The paper itself

Abstract

Transcatheter aortic valve implantation (TAVI) is a procedure to treat severe aortic stenosis. There are several clinical concerns related to potential complications after the procedure, which demand the analysis of computerized tomography (CT) scans after TAVI to assess the implant's result. This work introduces a novel, fully automatic method for the analysis of post-TAVI 4D-CT scans to characterize the prosthesis and its relationship with the patient's anatomy. The method enables measurement extraction, including prosthesis volume, center of mass, cross-sectional area (CSA) along the prosthesis axis, and CSA difference between the aortic root and prosthesis, all the variables studied throughout the cardiac cycle. The method has been implemented and evaluated with a cohort of 13 patients with five different prosthesis models, successfully extracting all the measurements from each patient in an automatic way. For Allegra patients, the mean of the obtained inner volume values ranged from 10,798.20 mm

Indexed as

artificial intelligence (AI)device-anatomy characterizationfour-dimensional computed tomography (4D-CT)fully automatic assessmenttranscatheter aortic valve implantation (TAVI)

Identifiers

PMID37892936
PMCPMC10604882
OpenAlexW4387673823

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.