Evidence map›Paper›PMID 37892867›Full record

ArticleBioengineering (Basel, Switzerland)2023

Treatment of Severe Pulmonary Regurgitation in Enlarged Native Right Ventricular Outflow Tracts: Transcatheter Pulmonary Valve Replacement with Three-Dimensional Printing Guidance.

Yiwei Wang, Ping Jin, Xin Meng, Lanlan Li, Yu Mao, Minwen Zheng, Liwen Liu, Yang Liu, Jian Yang

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yiwei WangDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
Ping JinDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
Xin MengDepartment of Ultrasound Medicine, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
Lanlan LiDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
Yu MaoDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
Minwen ZhengDepartment of Radiology, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
Liwen LiuDepartment of Ultrasound Medicine, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
Yang LiuDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
Jian YangDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.ORCID 0000-0003-2059-1912

Funding

Development and Transformation of New Technology and Construction of Precision Diagnosis and Treatment System for Transcatheter Interventional Diagnosis and Treatment of Structural Heart Diseases No. 2022YFC2503400Research on Key Techniques of Minimally Invasive Treatment for Valvular Heart Diseases No. 2023-YBSF-105
6 · The paper itself

Abstract

backgroundSevere pulmonary regurgitation (PR) often occurs following a transannular patch repair of tetralogy of Fallot, resulting in an enlarged native right ventricular outflow tract (nRVOT) with varying shapes.

methodsWe conducted a single-center study with eight patients having severe PR and enlarged nRVOT (diameters ≥ 29 mm). Transcatheter pulmonary valve replacement (TPVR) was performed using the self-expanding PT-Valve. Preoperative evaluation included echocardiography, computed tomography, and magnetic resonance imaging. A 3D-printed model of the nRVOT was used for preoperative assessment. Follow-up data were collected in 1-year follow-up.

resultsPT-Valve was successfully implanted in all patients, resulting in immediate improvement of severe PR. Pulmonary artery diastolic pressure increased significantly (

conclusion3D printing-guided PT-Valve implantation in enlarged nRVOT for severe PR is safe and effective, expanding TPVR indications and offering potential treatment for a broader patient population.

Indexed as

enlarged native right ventricular outflow tractPT-Valvepulmonary regurgitationthree-dimensional printingtranscatheter pulmonary valve replacement

Identifiers

PMID37892867
PMCPMC10604601

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.