Evidence map›Paper›PMID 37887870›Full record

ArticleJournal of cardiovascular development and disease2023

A Predictive and an Optimization Mathematical Model for Device Design in Cardiac Pulsed Field Ablation Using Design of Experiments.

Eoghan Dunne, Jara M Baena-Montes, Kevin Donaghey, Cormac Clarke, Marcin J Kraśny, Bilal Amin, Tony O'Halloran, Leo R Quinlan, Adnan Elahi, Martin O'Halloran

Open access · goldAbstract read
In one paragraph

Article in Journal of cardiovascular development and disease, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Role of Computational Modelling in Enhancing Thermal Safety During Cardiac Ablation.Interdisciplinary cardiovascular and thoracic surgery · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Eoghan DunneTranslational Medical Device Lab (TMD Lab), Lambe Institute for Translational Research, School of Medicine, University of Galway, H91 TK33 Galway, Ireland.
Jara M Baena-MontesPhysiology and Cellular Physiology Research Laboratory, CÚRAM SFI Centre for Research in Medical Devices, School of Medicine, Human Biology Building, University of Galway, H91 TK33 Galway, Ireland.ORCID 0000-0003-2331-5147
Kevin DonagheyAuriGen Medical, GMIT Innovation Hubs, H91 DCH9 Galway, Ireland.
Cormac ClarkeAuriGen Medical, GMIT Innovation Hubs, H91 DCH9 Galway, Ireland.
Marcin J KraśnyTranslational Medical Device Lab (TMD Lab), Lambe Institute for Translational Research, School of Medicine, University of Galway, H91 TK33 Galway, Ireland.ORCID 0000-0002-9281-1681
Bilal AminTranslational Medical Device Lab (TMD Lab), Lambe Institute for Translational Research, School of Medicine, University of Galway, H91 TK33 Galway, Ireland.ORCID 0000-0002-4340-1387
Tony O'HalloranAuriGen Medical, GMIT Innovation Hubs, H91 DCH9 Galway, Ireland.
Leo R QuinlanPhysiology and Cellular Physiology Research Laboratory, CÚRAM SFI Centre for Research in Medical Devices, School of Medicine, Human Biology Building, University of Galway, H91 TK33 Galway, Ireland.
Adnan ElahiTranslational Medical Device Lab (TMD Lab), Lambe Institute for Translational Research, School of Medicine, University of Galway, H91 TK33 Galway, Ireland.ORCID 0000-0003-0988-5776
Martin O'HalloranTranslational Medical Device Lab (TMD Lab), Lambe Institute for Translational Research, School of Medicine, University of Galway, H91 TK33 Galway, Ireland.
Ollscoil na Gaillimhe – University of Galway · IE

Funding

Government of Ireland DT20180031
6 · The paper itself

Abstract

Cardiac catheter ablation (CCA) is a common method used to correct cardiac arrhythmia. Pulsed Field Ablation (PFA) is a recently-adapted CCA technology whose ablation is dependent on electrode and waveform parameters (factors). In this work, the use of the Design of Experiments (DoE) methodology is investigated for the design and optimization of a PFA device. The effects of the four factors (input voltage, electrode spacing, electrode width, and on-time) and their interactions are analyzed. An empirical model is formed to predict and optimize the ablation size responses. Based on the ranges tested, the significant factors were the input voltage, the electrode spacing, and the on time, which is in line with the literature. Two-factor interactions were found to be significant and need to be considered in the model. The resulting empirical model was found to predict ablation sizes with less than 2.1% error in the measured area and was used for optimization. The findings and the strong predictive model developed highlight that the DoE approach can be used to help determine PFA device design, to optimize for certain ablation zone sizes, and to help inform device design to tackle specific cardiac arrhythmias.

Indexed as

atrial fibrillationcardiomyocytesdesign of experimentsin vitropulsed field ablation

Identifiers

PMID37887870
PMCPMC10607717
OpenAlexW4387572974

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.