Evidence map›Paper›PMID 37887630›Full record

ArticleBiomimetics (Basel, Switzerland)2023

Optimization of Fixations for Additively Manufactured Cranial Implants: Insights from Finite Element Analysis.

Fariha Haque, Anthony F Luscher, Kerry-Ann S Mitchell, Alok Sutradhar

Open access · goldAbstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Fariha HaqueDepartment of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, OH 43210, USA.
Anthony F LuscherDepartment of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, OH 43210, USA.
Kerry-Ann S MitchellDepartment of Plastic Surgery, The Ohio State University Wexner Medical Center, Columbus, OH 43210, USA.ORCID 0000-0002-2996-4837
Alok SutradharDepartment of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, OH 43210, USA.
The Ohio State University · USThe Ohio State University Wexner Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

With the emergence of additive manufacturing technology, patient-specific cranial implants using 3D printing have massively influenced the field. These implants offer improved surgical outcomes and aesthetic preservation. However, as additive manufacturing in cranial implants is still emerging, ongoing research is investigating their reliability and sustainability. The long-term biomechanical performance of these implants is critically influenced by factors such as implant material, anticipated loads, implant-skull interface geometry, and structural constraints, among others. The efficacy of cranial implants involves an intricate interplay of these factors, with fixation playing a pivotal role. This study addresses two critical concerns: determining the ideal number of fixation points for cranial implants and the optimal curvilinear distance between those points, thereby establishing a minimum threshold. Employing finite element analysis, the research incorporates variables such as implant shapes, sizes, materials, the number of fixation points, and their relative positions. The study reveals that the optimal number of fixation points ranges from four to five, accounting for defect size and shape. Moreover, the optimal curvilinear distance between two screws is approximately 40 mm for smaller implants and 60 mm for larger implants. Optimal fixation placement away from the center mitigates higher deflection due to overhangs. Notably, a symmetric screw orientation reduces deflection, enhancing implant stability. The findings offer crucial insights into optimizing fixation strategies for cranial implants, thereby aiding surgical decision-making guidelines.

Indexed as

cranial implantsfinite element analysisfixation pointspatient-specific design

Identifiers

PMID37887630
PMCPMC10603949
OpenAlexW4387781273

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.