Evidence map›Paper›PMID 37887596›Full record

ArticleBiomimetics (Basel, Switzerland)2023

The Impact of Left Ventricular Assist Device Outflow Graft Positioning on Aortic Hemodynamics: Improving Flow Dynamics to Mitigate Aortic Insufficiency.

Zhuohan Gu, Chi Wei Ong, Yongzhen Mi, Ashwin Seetharaman, Ryan Ruiyang Ling, Kollengode Ramanathan, Hwa Liang Leo

Open access · goldAbstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Hemodynamic analysis of the aortic root based on differences in outflow graft angle in patients with implantable left ventricular assist devices.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2026
    Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Zhuohan GuDepartment of Biomedical Engineering, National University of Singapore, Singapore 119077, Singapore.ORCID 0009-0005-1076-6549
Chi Wei OngSchool of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, Singapore 639798, Singapore.ORCID 0000-0002-5354-0380
Yongzhen MiInstitute of High Performance Computing (IHPC), Agency for Science, Technology and Research (A*STAR), Singapore 138632, Singapore.ORCID 0000-0001-9294-4284
Ashwin SeetharamanDepartment of Biomedical Engineering, National University of Singapore, Singapore 119077, Singapore.ORCID 0000-0001-8686-2338
Ryan Ruiyang LingYong Loo Lin School of Medicine, National University of Singapore, Singapore 119228, Singapore.ORCID 0000-0002-8335-7640
Kollengode RamanathanYong Loo Lin School of Medicine, National University of Singapore, Singapore 119228, Singapore.ORCID 0000-0003-1822-9455
Hwa Liang LeoDepartment of Biomedical Engineering, National University of Singapore, Singapore 119077, Singapore.
National University of Singapore · SGAgency for Science, Technology and Research · SGNanyang Technological University · SG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Heart failure is a global health concern with significant implications for healthcare systems. Left ventricular assist devices (LVADs) provide mechanical support for patients with severe heart failure. However, the placement of the LVAD outflow graft within the aorta has substantial implications for hemodynamics and can lead to aortic insufficiency during long-term support. This study employs computational fluid dynamics (CFD) simulations to investigate the impact of different LVAD outflow graft locations on aortic hemodynamics. The introduction of valve morphology within the aorta geometry allows for a more detailed analysis of hemodynamics at the aortic root. The results demonstrate that the formation of vortex rings and subsequent vortices during the high-velocity jet flow from the graft interacted with the aortic wall. Time-averaged wall shear stress (TAWSS) and oscillatory shear index (OSI) indicate that modification of the outflow graft location changes mechanical states within the aortic wall and aortic valve. Among the studied geometric factors, both the height and inclination angle of the LVAD outflow graft are important in controlling retrograde flow to the aortic root, while the azimuthal angle primarily determines the rotational direction of blood flow in the aortic arch. Thus, precise positioning of the LVAD outflow graft emerges as a critical factor in optimizing patient outcomes by improving the hemodynamic environment.

Indexed as

aortic insufficiencyaortic valvecomputational fluid dynamicsLVAD

Identifiers

PMID37887596
PMCPMC10604423
OpenAlexW4387265295

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.