Evidence map›Paper›PMID 37886407›Full record

Article3D printing and additive manufacturing2023

A Novel Approach of Customized Pelvic Implant Design Based on Symmetrical Analysis and 3D Printing.

Yuan Chai, Xiao-Bo Chen, Jesse A Estoque, Nick Birbilis, Qinghua Qin, Tomas Ward, Paul N Smith, Rachel W Li

Abstract read
In one paragraph

Article in 3D printing and additive manufacturing, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Comparison of 2 open-sourced 3-dimensional modeling techniques for orthopaedic application.OTA international : the open access journal of orthopaedic trauma · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yuan ChaiTrauma and Orthopaedic Research Laboratory, Department of Surgery, The Medical School, The Australian National University, Canberra, Australian Capital Territory, Australia.ORCID https://orcid.org/0000-0001-6977-6155
Xiao-Bo ChenSchool of Engineering, RMIT University, Carlton, Victoria, Australia.
Jesse A EstoqueTrauma and Orthopaedic Research Laboratory, Department of Surgery, The Medical School, The Australian National University, Canberra, Australian Capital Territory, Australia.
Nick BirbilisCollege of Engineering and Computer Science, The Australian National University, Canberra, Australian Capital Territory, Australia.
Qinghua QinCollege of Engineering and Computer Science, The Australian National University, Canberra, Australian Capital Territory, Australia.
Tomas WardDepartment of Emergency, The Canberra Hospital, Canberra, Australian Capital Territory, Australia.
Paul N SmithTrauma and Orthopaedic Research Unit, Clinical Orthopaedic Surgery, The Canberra Hospital, Canberra, Australian Capital Territory, Australia.
Rachel W LiJohn Curtin School of Medical Research, The Australian National University, Acton, Australian Capital Territory, Australia.ORCID https://orcid.org/0000-0001-7053-7928

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In pelvic trauma patients, the mismatch of complex geometries between the pelvis and fixation implant is a fundamental cause of unstable and displaced pelvic ring disruption, in which secondary intervention is strongly considered. The geometrical matching in the current customized implant design and clinical practice is through the nonfractured hemi-pelvis for the fractured pelvis. This design philosophy overlooks the anatomical difference between the hemipelves, and further, the geometrical asymmetry at local area still remains unknown. This study analyzed the anatomical asymmetry of a patient's 3D pelvic models from 13 patients. The hemipelves of each patient were registered by using an iterative closet algorithm to an optimum position with minimum deviations. The high deviation regions were summarized between the hemipelves in each case, and a color map was drawn on a hemipelvis model that identified the areas that had a high possibility to be symmetrically different. A severe pelvic trauma case was used to comprehend the approach by designing a 3D printed implant. Each fracture was then registered to the mirrored uninjured hemipelvis by using the same algorithm, and customized fixation implants were designed with reference to the fractured model. The customized fixation plates showed that the implants had lower geometrical deviation when attached onto the re-stitched fracture side than onto the mirrored nonfractured bone. These results indicate that the symmetrical analysis of bone anatomy and the deviation color map can assist with implant selection and customized implant design given the geometrical difference between symmetrical bones. The novel approach provides a scientific reference that improves the accuracy and overall standard of 3D printed implants.

Indexed as

3D printinganatomical designcustomized implantgeometrical fitpelvic fracturesymmetrical analysis

Identifiers

PMID37886407
PMCPMC10599429

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.