Evidence map›Paper›PMID 37884628›Full record

ArticleScientific reports2023

The second clinical study investigating the surgical method for the kineticomyographic control implementation of the bionic hand.

Mahla Daliri, Alireza Akbarzadeh, Behzad Aminzadeh, Amir R Kachooei, Ghazaleh Hajiaghajani, Mohammad H Ebrahimzadeh, Ali Moradi

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Mahla DaliriOrthopedics Research Center, Ghaem Hospital, Mashhad University of Medical Sciences, Mashhad, Iran.ORCID 0000-0001-8722-1129
Alireza AkbarzadehMechanical Engineering Department, Ferdowsi University of Mashhad, Mashhad, Iran.ORCID 0000-0001-8605-8956
Behzad AminzadehDepartment of Radiology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.ORCID 0000-0001-6569-4670
Amir R KachooeiOrthopedics Research Center, Ghaem Hospital, Mashhad University of Medical Sciences, Mashhad, Iran.
Ghazaleh HajiaghajaniOrthopedics Research Center, Ghaem Hospital, Mashhad University of Medical Sciences, Mashhad, Iran.
Mohammad H EbrahimzadehOrthopedics Research Center, Ghaem Hospital, Mashhad University of Medical Sciences, Mashhad, Iran.ORCID 0000-0003-2219-8524
Ali MoradiOrthopedics Research Center, Ghaem Hospital, Mashhad University of Medical Sciences, Mashhad, Iran. almor0012@gmail.com.ORCID 0000-0001-5796-8774
Mashhad University of Medical Sciences · IRFerdowsi University of Mashhad · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In 2018, during our first clinical study on the kineticomyographic (KMG)-controlled bionic hand, we implanted three magnetic tags inside the musculotendinous junction of three paired extensor-flexor transferred tendons. However, the post-operative tissue adhesions affected the independent movements of the implanted tags and consequently the distinct patterns of the obtained signals. To overcome this issue, we modified our surgical procedure from a one-stage tendon transfer to a two-stage. During the first surgery, we created three tunnels using silicon rods for the smooth tendon gliding. In the second stage, we transferred the same three pairs of the forearm agonist-antagonist tendons through the tunnels and implanted the magnetic tags inside the musculotendinous junction. Compared to our prior clinical investigation, fluoroscopy and ultrasound evaluations revealed that the surgical modification in the current study yielded more pronounced independent movements in two specific magnetic tags associated with fingers (maximum 5.7 mm in the first trial vs. 28 mm in the recent trial with grasp and release) and thumb (maximum 3.2 mm in the first trial vs. 9 mm in the current trial with thumb flexion-extension). Furthermore, we observed that utilizing the flexor digitorum superficialis (FDS) tendons for the flexor component in finger and thumb tendon transfer resulted in more independent movements of the implanted tags, compared with the flexor digitorum profundus (FDP) in the prior research. This study can help us plan for our future five-channel bionic limb design by identifying the gestures with the most significant independent tag displacement.

Indexed as

BionicsTendonsFingersMuscle, SkeletalTendon Transfer

Identifiers

PMID37884628
PMCPMC10603097
OpenAlexW4387966031

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.