ArticleInternational journal of surgery case reports2023

Delay in diagnosis of urethral perforation due to catheterisation in a person with cervical spinal cord injury. Importance of (1) imaging studies done promptly for detection and documentation of urethral trauma, (2) Urethrotech catheterisation device to minimise urethral trauma and achieve successful catheterisation: A case report.

Vaidyanathan Subramanian, Bakulesh Madhusudan Soni, Peter Lyndon Hughes, Rauf Nabil Khadr

Open access · goldAbstract readCase Reports
In one paragraph

Article in International journal of surgery case reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Vaidyanathan SubramanianRegional Spinal Injuries Centre, Southport and Formby District General Hospital, Town Lane, Southport PR8 6PN, United Kingdom. Electronic address: subramanian.vaidyanathan@nhs.net.
Bakulesh Madhusudan SoniRegional Spinal Injuries Centre, Southport and Formby District General Hospital, Town Lane, Southport PR8 6PN, United Kingdom. Electronic address: bakul.soni@nhs.net.
Peter Lyndon HughesDepartment of Radiology, Southport and Formby District General Hospital, Town Lane, Southport PR8 6PN, United Kingdom. Electronic address: peterhughes1@nhs.net.
Rauf Nabil KhadrDepartment of Urology, Southport and Formby District General Hospital, Town Lane, Southport PR8 6PN, United Kingdom. Electronic address: rauf.khadr@nhs.net.
Southport and Formby District General Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introduction and importanceSpinal cord injury patients are at risk for urethral trauma during catheterisation. We report a patient in whom urethral perforation due to catheterisation was not recognised for ∼ four days. CASE PRESENTATION: Following a routine catheter change by community nurses in a male person with tetraplegia, the catheter drained only a small amount of urine. Therefore, the patient attended the hospital where the staff removed the catheter but could not place a new catheter. The doctor tried different catheters and on fifth attempt, inserted a catheter. The patient continued to bypass urine and was prescribed Solifenacin. On self-referral to spinal unit, urethral trauma was suspected. CT of pelvis revealed the balloon of the Foley catheter in the penile urethra at penis base with the tip projecting beyond the penile shaft. Suprapubic cystostomy was done. The patient continued to leak urine from the penis; required penile sheath drainage and an additional leg bag. CLINICAL DISCUSSION: This case illustrates the value of CT of pelvis including the penis in detecting urethral trauma and misplacement of the catheter. Physicians should look for symptoms and signs of urethral trauma and incorrect positioning of the catheter. Imaging studies should be done without delay to assess urethral trauma and misplacement of urinary catheter.

conclusionWe use Urethrotech urethral catheterisation in patients in whom the first attempt to insert a catheter per urethra is unsuccessful, or in patients with a history of difficult catheterisation. This helped to minimise urethral trauma and achieve successful catheterisation.

Indexed as

Cervical spinal cord injuryIatrogenicPenile urethraSuprapubic cystostomyUrethral catheterisationUrethral catheterisation device

Identifiers

PMID37883868
PMCPMC10667899
OpenAlexW4387924426

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.