Artificial Intelligence-Driven Single-Shot PET Image Artifact Detection and Disentanglement: Toward Routine Clinical Image Quality Assurance.

Isaac Shiri, Yazdan Salimi, Elsa Hervier, Agathe Pezzoni, Amirhossein Sanaat, Shayan Mostafaei, Arman Rahmim, Ismini Mainta, Habib Zaidi

Open access · hybridAbstract read
In one paragraph

Article in Clinical nuclear medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 3 countries.

Isaac Shiri
Yazdan SalimiFrom the Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva.
Elsa HervierFrom the Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva.
Agathe PezzoniFrom the Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva.
Amirhossein SanaatFrom the Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva.
Shayan Mostafaei
Arman Rahmim
Ismini MaintaFrom the Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva.
Habib Zaidi
University of Bern · CHKarolinska Institutet · SEUniversity of British Columbia · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeMedical imaging artifacts compromise image quality and quantitative analysis and might confound interpretation and misguide clinical decision-making. The present work envisions and demonstrates a new paradigm PET image Quality Assurance NETwork (PET-QA-NET) in which various image artifacts are detected and disentangled from images without prior knowledge of a standard of reference or ground truth for routine PET image quality assurance.

methodsThe network was trained and evaluated using training/validation/testing data sets consisting of 669/100/100 artifact-free oncological 18 F-FDG PET/CT images and subsequently fine-tuned and evaluated on 384 (20% for fine-tuning) scans from 8 different PET centers. The developed DL model was quantitatively assessed using various image quality metrics calculated for 22 volumes of interest defined on each scan. In addition, 200 additional 18 F-FDG PET/CT scans (this time with artifacts), generated using both CT-based attenuation and scatter correction (routine PET) and PET-QA-NET, were blindly evaluated by 2 nuclear medicine physicians for the presence of artifacts, diagnostic confidence, image quality, and the number of lesions detected in different body regions.

resultsAcross the volumes of interest of 100 patients, SUV MAE values of 0.13 ± 0.04, 0.24 ± 0.1, and 0.21 ± 0.06 were reached for SUV mean , SUV max , and SUV peak , respectively (no statistically significant difference). Qualitative assessment showed a general trend of improved image quality and diagnostic confidence and reduced image artifacts for PET-QA-NET compared with routine CT-based attenuation and scatter correction.

conclusionWe developed a highly effective and reliable quality assurance tool that can be embedded routinely to detect and correct for 18 F-FDG PET image artifacts in clinical setting with notably improved PET image quality and quantitative capabilities.

Indexed as

Fluorodeoxyglucose F18Positron Emission Tomography Computed TomographyArtifactsArtificial IntelligenceHumansImage Processing, Computer-AssistedPositron-Emission TomographyFluorodeoxyglucose F18

Identifiers

PMID37883015
PMCPMC10662584
OpenAlexW4387950698

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.