Evidence map›Paper›PMID 37881287›Full record

ArticleIndian journal of orthopaedics2023

Intra-operative Safety of an Autonomous Robotic System for Total Knee Replacement: A Review of 500 Cases in India.

P Chandrashekar, K Adarsh Babu, H S Nagaraja, S Gangu Hiral, S Karthikeyan, Supreet Bajwa

Open access · greenAbstract read
In one paragraph

Article in Indian journal of orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.9field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Observational
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

P ChandrashekarInstitute of Orthopaedics, Sakra World Hospital, Devarabeesanahalli, Bangalore, India.
K Adarsh BabuInstitute of Orthopaedics, Sakra World Hospital, Devarabeesanahalli, Bangalore, India.
H S NagarajaInstitute of Orthopaedics, Sakra World Hospital, Devarabeesanahalli, Bangalore, India.
S Gangu HiralInstitute of Orthopaedics, Sakra World Hospital, Devarabeesanahalli, Bangalore, India.
S KarthikeyanInstitute of Orthopaedics, Sakra World Hospital, Devarabeesanahalli, Bangalore, India.
Supreet BajwaHip and Knee Specialist, Wockhardt Hospital, 1877, Dr Anandrao Nair Marg, Near Agripada, Mumbai Central, Mumbai, Maharashtra India.ORCID 0000-0003-2325-7653
Wockhardt Hospitals · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Manual total knee arthroplasty (TKA) has been documented several times for their safety and complications data. In contrast, there is a limited evidence-based analysis for safety and complications of autonomous robotic-assisted (RA)-TKA. This study aimed to evaluate the safety features and intra-operative surgical complications associated with the use of Cuvis Joint™ autonomous robotic system for TKA. Methods: The study included 500 consecutive patients who underwent TKA using the Cuvis Joint™ autonomous robotic system from November 2020 to November 2021. All surgeries were performed by a senior surgeon. Patients in whom the surgery was abandoned midway due to technical errors, were excluded from the analysis. In case of unilateral abandonment of the robotic arm during a bilateral RA-TKA, data of the side on which the surgery was completed with robotic assistance was recorded. Results: There was no incidence of neurological injury, vascular injury, extensor mechanism disruption, or medial collateral ligament injury. There was one case of superficial abrasion of the patellar tendon; however, it did not require any intervention. There were no cases of midway abandonment due to threatened soft tissue injury. There was no intra-operative pin loosening or stress-related fractures at the pin sites. There was one case of Steinmann pin breakage and another case of drill bit breakage, which were removed without any damage to the bone. Conclusion: The Cuvis Joint™ autonomous robotic system for TKA is safe with no significant intra-operative complications.

Indexed as

Active robotic total knee arthroplastyAutonomous robotCuvis JointIntra-operative complicationsRobotic-arm assisted total knee arthroplasty

Identifiers

PMID37881287
PMCPMC10593704
OpenAlexW4386462002

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.