Evidence map›Paper›PMID 37878957›Full record

Observational studyCoDAS2023

Hearing rehabilitation with Baha® transcutaneous and percutaneous systems.

Eliane Aparecida Techi Castiquini, Kátia de Freitas Alvarenga, Lucilena Miranda de Souza, Valdéia Vieira de Oliveira, Juliana Nogueira Chaves, Luiz Fernando Manzoni Lourençone, Rubens Vuono de Brito Neto

Open access · diamondAbstract readObservational Study
In one paragraph

Observational study in CoDAS, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 49% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Eliane Aparecida Techi CastiquiniDivisão de Saúde Auditiva, Hospital de Reabilitação de Anomalias Craniofaciais - HRAC, Universidade de São Paulo - USP - Bauru (SP), Brasil.ORCID http://orcid.org/0000-0002-1984-1438
Kátia de Freitas AlvarengaDepartamento de Fonoaudiologia, Faculdade de Odontologia de Bauru - FOB, Universidade de São Paulo - USP - Bauru (SP), Brasil.ORCID http://orcid.org/0000-0002-7847-3225
Lucilena Miranda de SouzaPrograma de Residência Multiprofissional em Saúde Auditiva, Hospital de Reabilitação de Anomalias Craniofaciais - HRAC, Universidade de São Paulo - USP - Bauru (SP), Brasil.ORCID http://orcid.org/0000-0001-7109-4196
Valdéia Vieira de OliveiraDivisão de Saúde Auditiva, Hospital de Reabilitação de Anomalias Craniofaciais - HRAC, Universidade de São Paulo - USP - Bauru (SP), Brasil.ORCID http://orcid.org/0000-0002-0123-4963
Juliana Nogueira ChavesDivisão de Saúde Auditiva, Hospital de Reabilitação de Anomalias Craniofaciais - HRAC, Universidade de São Paulo - USP - Bauru (SP), Brasil.ORCID http://orcid.org/0000-0002-4727-7408
Luiz Fernando Manzoni LourençoneHospital de Reabilitação de Anomalias Craniofaciais - HRAC, Universidade de São Paulo - USP - Bauru (SP), Brasil.ORCID http://orcid.org/0000-0002-5935-3148
Rubens Vuono de Brito NetoDepartamento de Fonoaudiologia, Faculdade de Odontologia de Bauru - FOB, Universidade de São Paulo - USP - Bauru (SP), Brasil.ORCID http://orcid.org/0000-0001-5313-5214
Universidade de São Paulo · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeLongitudinally verify the influence of auditory tonal thresholds obtained with transcutaneous and percutaneous bone-anchored hearing aids on speech perception in individuals with external and/or middle ear malformation and chronic otitis media.

methodsObservational, retrospective, longitudinal follow-up study of 30 unilateral users of the transcutaneous and percutaneous Baha® system for the collection of secondary data on pure tone thresholds obtained through free field audiometry and sentence recognition threshold in silence and noise in conditions: without the prosthesis; at the time of activation; in the first month of use (post 1); and in the third month (post 2).

resultsThere was a significant difference between pure tone thresholds obtained at frequencies of 3 and 4kHz with better results for the percutaneous technique at all evaluation moments. For both systems, better performance was observed in sentence recognition in silence and in noise, with a significant difference in activation (p<0.001), but it remained stable during the other evaluation moments. The percutaneous system showed better benefit in recognizing sentences in noise only on activation (p=0.036), when compared to the transcutaneous system.

conclusionThe percutaneous system provided better audibility for high frequencies; however, such audibility did not influence sentence recognition in the silent situation for both systems. For the noise situation, better responses were observed in the percutaneous system, however, the difference was not maintained over time.

Indexed as

Hearing AidsSpeech PerceptionFollow-Up StudiesHearingHearing TestsHumansRetrospective Studies

Identifiers

PMID37878957
PMCPMC10715577
OpenAlexW4387875566

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.