Evidence map›Paper›PMID 37875630›Full record

Observational studyEuropean journal of pediatrics2024

Accuracy of liquid drug dose measurements using different tools by caregivers: a prospective observational study.

Burcu Bayraktar Balıkçı, Ülkü Güneş

Abstract readObservational Study
PubMed Publisher
In one paragraph

Observational study in European journal of pediatrics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.2field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 2 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Burcu Bayraktar BalıkçıDepartment of Anesthesiology and Reanimation, Faculty of Medicine Hospital, Ege University, 35040, Izmir, Turkey. burcu.byrktr@hotmail.com.ORCID http://orcid.org/0000-0003-3678-8701
Ülkü GüneşDepartment of Fundamentals of Nursing, Faculty of Nursing, Ege University, 35040, Izmir, Turkey.ORCID http://orcid.org/0000-0001-8104-5603
Ege University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to assess the accuracy of liquid drug dose measurements made by caregivers and explore the factors influencing these measurements. Caregivers (n = 176) of children aged less than 8 years, who were treated at the pediatric clinic of a university hospital in Turkey between July and October 2019, were eligible to participate in this study. The caregivers' ability to accurately measure a 2.5-mL dose of medication was observed using standardized measurement instruments, including 15-mL and 30-mL dosing cups, a 3-mL dropper, a 5-mL dose spoon, and a 5-mL oral syringe. A comparison was made with the reference weight determined for the 2.5-mL dose to calculate the margin of error. A dose of ± 20% of the reference value was considered a clinically significant error. The chi-square test was used to examine differences in dose error rates concerning individual characteristics. Caregivers exhibited a dosing error rate exceeding 20%. Specifically, 43% of the errors occurred when using 15-mL cups, 37% with 30-mL cups, 22% with 3-mL droppers, 4.5% with 5-mL spoons, and 4% with 5-mL syringes. In cases where errors were under 20%, the rates were as follows: 1.1% with 15-mL cups, 2.8% with 30-mL cups, 19% with 3-mL droppers, 3.4% with 5-mL spoons, and 4% with 5-mL syringes. The dosing errors were not affected by the role and health literacy level of caregivers, regardless of the type of dosing tool they used (all p values > 0.05). The study found that oral syringes and dosing spoons had the lowest error rates, whereas dosing cups had the highest error rates.  Conclusion: Healthcare providers in family health centers and pediatric clinics should educate caregivers about proper drug administration with oral syringes and dosing spoons, even if dosing cups are included. What is Known: • Dose calculation errors and incorrect measurement tools are the leading factors causing errors. • Liquid medicine bottles are still often accompanied by dosing cups as measuring instruments. • Both the American Academy of Pediatrics (AAP) and the U.S. Food and Drug Administration (FDA) recommend that parents use standard measuring instruments such as oral syringes, droppers, and measuring spoons instead of kitchen spoons for administering the correct dose to children. What is New: • The measuring tool with the maximum errors was the dosing cup, whereas oral syringes and dosing spoons were more accurate. • Individual administering medication at home and the health literacy level had no effect on the accuracy of dose measurement. • Pediatric nurses, in particular, should incorporate safe liquid medication measurement tools into parental education.

Indexed as

Health LiteracyMedication ErrorsCaregiversChildHumansParentsReference ValuesCaregiversMedication errorsNursingOral drug administration

Identifiers

PMID37875630
OpenAlexW4387898241

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.