Evidence map›Paper›PMID 37873236›Full record

ArticlemedRxiv : the preprint server for health sciences2023

Reproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation.

Leening P Liu, Rizza Pua, Derick N Rosario-Berrios, Olivia F Sandvold, Amy E Perkins, David P Cormode, Nadav Shapira, Michael C Soulen, Peter B Noël

Abstract readPreprint
In one paragraph

Article in medRxiv : the preprint server for health sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

9 authors.

Funding

Interventional oncology clinical research specialistR50CA276008 · NCI · UNIVERSITY OF PENNSYLVANIA · PI MICHAEL C SOULEN · 2023 to 2026
$692k
NCI NIH HHS R50 CA276008
6 · The paper itself

Abstract

Objectives: Evaluate the reproducibility, temperature sensitivity, and radiation dose requirements of spectral CT thermometry in tissue-mimicking phantoms to establish its utility for non-invasive temperature monitoring of thermal ablations. Materials and Methods: Three liver mimicking phantoms embedded with temperature sensors were individually scanned with a dual-layer spectral CT at different radiation dose levels during heating and cooling (35 to 80 °C). Physical density maps were reconstructed from spectral results using a range of reconstruction parameters. Thermal volumetric expansion was then measured at each temperature sensor every 5°C in order to establish a correlation between physical density and temperature. Linear regressions were applied based on thermal volumetric expansion for each phantom, and coefficient of variation for fit parameters was calculated to characterize reproducibility of spectral CT thermometry. Additionally, temperature sensitivity was determined to evaluate the effect of acquisition parameters, reconstruction parameters, and image denoising. The resulting minimum radiation dose to meet the clinical temperature sensitivity requirement was determined for each slice thickness, both with and without additional denoising. Results: Thermal volumetric expansion was robustly replicated in all three phantoms, with a correlation coefficient variation of only 0.43%. Similarly, the coefficient of variation for the slope and intercept were 9.6% and 0.08%, respectively, indicating reproducibility of the spectral CT thermometry. Temperature sensitivity ranged from 2 to 23 °C, decreasing with increased radiation dose, slice thickness, and iterative reconstruction level. To meet the clinical requirement for temperature sensitivity, the minimum required radiation dose ranged from 20, 30, and 57 mGy for slice thickness of 2, 3, and 5 mm, respectively, but was reduced to 2 mGy with additional denoising. Conclusions: Spectral CT thermometry demonstrated reproducibility across three liver-mimicking phantoms and illustrated the clinical requirement for temperature sensitivity can be met for different slice thicknesses. Moreover, additional denoising enables the use of more clinically relevant radiation doses, facilitating the clinical translation of spectral CT thermometry. The reproducibility and temperature accuracy of spectral CT thermometry enable its clinical application for non-invasive temperature monitoring of thermal ablation.

Identifiers

PMID37873236
PMCPMC10593007

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.