Evidence map›Paper›PMID 37873053›Full record

ArticleDEN open2024

The novel technique of drainage stenting using a tapered sheath dilator in endoscopic ultrasound-guided biliary drainage.

Akihisa Kato, Michihiro Yoshida, Yasuki Hori, Kenta Kachi, Hidenori Sahashi, Tadashi Toyohara, Akihisa Adachi, Kayoko Kuno, Yusuke Kito, Hiromi Kataoka

Open access · goldAbstract read
In one paragraph

Article in DEN open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Use of a Large-Caliber Endoscopic Sheath to Prevent Device Deflection During EUS-Guided Antegrade Stone Removal.Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · 2026
    Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Akihisa KatoDepartment of Gastroenterology and Metabolism Nagoya City University Graduate School of Medical Sciences Aichi Japan.ORCID https://orcid.org/0000-0002-7733-7854
Michihiro YoshidaDepartment of Gastroenterology and Metabolism Nagoya City University Graduate School of Medical Sciences Aichi Japan.
Yasuki HoriDepartment of Gastroenterology and Metabolism Nagoya City University Graduate School of Medical Sciences Aichi Japan.
Kenta KachiDepartment of Gastroenterology and Metabolism Nagoya City University Graduate School of Medical Sciences Aichi Japan.
Hidenori SahashiDepartment of Gastroenterology and Metabolism Nagoya City University Graduate School of Medical Sciences Aichi Japan.
Tadashi ToyoharaDepartment of Gastroenterology and Metabolism Nagoya City University Graduate School of Medical Sciences Aichi Japan.
Akihisa AdachiDepartment of Gastroenterology and Metabolism Nagoya City University Graduate School of Medical Sciences Aichi Japan.
Kayoko KunoDepartment of Gastroenterology and Metabolism Nagoya City University Graduate School of Medical Sciences Aichi Japan.
Yusuke KitoDepartment of Gastroenterology and Metabolism Nagoya City University Graduate School of Medical Sciences Aichi Japan.
Hiromi KataokaDepartment of Gastroenterology and Metabolism Nagoya City University Graduate School of Medical Sciences Aichi Japan.
Nagoya City University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

During endoscopic ultrasound-guided biliary drainage (EUS-BD), there is a risk for bile leakage until stent deployment, which can result in severe peritonitis, particularly when passing a drainage stent becomes challenging despite tract dilation. There is no established method or dedicated device to optimize EUS-BD. Therefore, we have developed a novel stent deployment technique using the tapered sheath dilator. To address the safety and technical aspects of the EUS-BD technique, we retrospectively analyzed 11 consecutive patients who underwent EUS-BD using the tapered sheath dilator. The procedure involved the insertion of a guidewire, followed by mechanical dilation using the tapered sheath dilator. Subsequently, the inner catheter was removed and drainage stents (up to 6 Fr in diameter) were deployed through the outer sheath. We found a 100% technical success rate for tract dilation and stent deployment; moreover, all patients achieved clinical success. The median time for dilation was 40 s (range, 8-198), whereas the median time from dilation to stent deployment was 10 min (range, 6-19). Notably, no cases of bile leakage or peritonitis were observed. In conclusion, the use of the integrated device for tract dilation and stent delivery system might provide a safe and straightforward technique for drainage stenting during EUS-BD.

Indexed as

bile leakagebiliary drainageEndosheatherEUS‐BDtapered sheath dilator

Identifiers

PMID37873053
PMCPMC10590603
OpenAlexW4387859563

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.