Evidence map›Paper›PMID 37872984›Full record

ArticleBiomedical engineering letters2023

Ventricle tracking in transesophageal echocardiography (TEE) images during cardiopulmonary resuscitation (CPR) using deep learning and monogenic filtering.

Honggi Ahn, Sun Ju Kim, Seungyoung Kang, Junghun Han, Sung Oh Hwang, Kyoung-Chul Cha, Sejung Yang

Abstract read
In one paragraph

Article in Biomedical engineering letters, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Honggi AhnDepartment of Biomedical Engineering, Yonsei University, 26493 Wonju, Republic of Korea.
Sun Ju KimDepartment of Emergency Medicine, Yonsei University Wonju College of Medicine, 20, Ilsan-ro, Wonju, Gangwon-do 26426 Republic of Korea.
Seungyoung KangDepartment of Biomedical Engineering, Yonsei University, 26493 Wonju, Republic of Korea.
Junghun HanDepartment of Biomedical Engineering, Yonsei University, 26493 Wonju, Republic of Korea.
Sung Oh HwangDepartment of Emergency Medicine, Yonsei University Wonju College of Medicine, 20, Ilsan-ro, Wonju, Gangwon-do 26426 Republic of Korea.
Kyoung-Chul ChaDepartment of Emergency Medicine, Yonsei University Wonju College of Medicine, 20, Ilsan-ro, Wonju, Gangwon-do 26426 Republic of Korea.
Sejung YangDepartment of Precision Medicine, Yonsei University Wonju College of Medicine, 20, Ilsan-ro, Wonju, Gangwon-do 26426 Republic of Korea.ORCID 0000-0002-5841-851X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

High-quality cardiopulmonary resuscitation (CPR) is the most important factor in promoting resuscitation outcomes; therefore, monitoring the quality of CPR is strongly recommended in current CPR guidelines. Recently, transesophageal echocardiography (TEE) has been proposed as a potential real-time feedback modality because physicians can obtain clear echocardiographic images without interfering with CPR. The quality of CPR would be optimized if the myocardial ejection fraction (EF) could be calculated in real-time during CPR. We conducted a study to derive a protocol to detect systole and diastole automatically and calculate EF using TEE images acquired from patients with cardiac arrest. The data were supplemented using thin-plate spline transformation to solve the problem of insufficient data. The deep learning model was constructed based on ResUNet +  + , and a monogenic filtering method was applied to clarify the ventricular boundary. The performance of the model to which the monogenic filter was added and the existing model was compared. The left ventricle was segmented in the ME LAX view, and the left and right ventricles were segmented in the ME four-chamber view. In most of the results, the performance of the model to which the monogenic filter was added was high, and the difference was very small in some cases; but the performance of the existing model was high. Through this learned model, the effect of CPR can be quantitatively analyzed by segmenting the ventricle and quantitatively analyzing the degree of contraction of the ventricle during systole and diastole. Supplementary Information: The online version contains supplementary material available at 10.1007/s13534-023-00293-9.

Indexed as

Cardiopulmonary resuscitation (CPR)Deep learning (DL)Ejection fraction (EF)Transesophageal echocardiography (TEE)

Identifiers

PMID37872984
PMCPMC10590343

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.