Evidence map›Paper›PMID 37872752›Full record

ArticleJournal of audiology & otology2023

Improving Accuracy and Reliability of Hearing Tests: An Exploration of International Standards.

Michelle J Suh, Jihyun Lee, Wan-Ho Cho, In-Ki Jin, Tae Hoon Kong, Soo Hee Oh, Hyo-Jeong Lee, Seong Jun Choi, Dongchul Cha, Kyung-Ho Park and 1 more

Abstract read
In one paragraph

Article in Journal of audiology & otology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Revisiting Age-Related Normative Hearing Levels in Korea.Journal of Korean medical science · 2025
    Article
  10. Article
  11. Article
  12. Article
  13. A prognostic value of estimated pulse wave velocity in idiopathic sudden sensorineural hearing loss.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2024
    Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Michelle J SuhDepartment of Otorhinolaryngology, Jeju National University College of Medicine, Jeju, Korea.
Jihyun LeeDepartment of Otorhinolaryngology, Yonsei University Wonju College of Medicine, Wonju, Korea.
Wan-Ho ChoDivision of Physical Metrology, Korea Research Institute of Standards and Science, Daejeon, Korea.
In-Ki JinDivision of Speech Pathology and Audiology, Research Institute of Audiology and Speech Pathology, College of Natural Sciences, Hallym University, Chuncheon, Korea.
Tae Hoon KongDepartment of Otorhinolaryngology, Yonsei University Wonju College of Medicine, Wonju, Korea.
Soo Hee OhDepartment of Audiology and Speech Language Pathology, Hallym Univesity of Graduate Studies, Seoul, Korea.
Hyo-Jeong LeeDepartment of Otorhinolaryngology-Head and Neck Surgery, Hallym University College of Medicine, Anyang, Korea.
Seong Jun ChoiDepartment of Otorhinolaryngology-Head and Neck Surgery, Soonchunhyang University Cheonan Hospital, Soonchunhyang University College of Medicine, Cheonan, Korea.
Dongchul ChaHealthcare Lab, Naver Corporation, Seongnam, Korea.
Kyung-Ho ParkDepartment of Otorhinolaryngology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Young Jun SeoDepartment of Otorhinolaryngology, Yonsei University Wonju College of Medicine, Wonju, Korea.

Funding

Ministry of Education 2022RIS-005National Research Foundation of Korea
6 · The paper itself

Abstract

This study explores the internal standards for hearing tests and benefits of implementing international standard protocols, including the International Organization for Standardization (ISO) and International Electrotechnical Commission (IEC), and discusses how ISO and IEC standards provide a framework for designing, calibrating, assessing hearing test instruments and methods, and exchanging and comparing data globally. ISO and IEC standards for hearing tests improve accuracy, reliability, and consistency of test results by applying standardized methods and environments. Moreover, they promote international harmonization and data interoperability, enabling information exchange and research collaboration. Those standards for hearing tests are beneficial but have challenges and limitations, such as variation in equipment and calibration, lag in updating standards, variation in implementation and compliance, and lack of coverage of clinical aspects, cultural diversity, and linguistic diversity. These affect the quality and interpretation of test results. Adapting ISO or IEC standards locally would improve their applicability and acceptability, while balancing customization and compatibility with global standards.

Indexed as

HearingtestsStandardization

Identifiers

PMID37872752
PMCPMC10603284

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.