Evidence map›Paper›PMID 37870728›Full record

ArticlePhysical and engineering sciences in medicine2024

A position-adaptive noise-reduction method using a deep denoising filter bank for dedicated breast positron emission tomography images.

Masahiro Tsukijima, Atsushi Teramoto, Akihiro Kojima, Osamu Yamamuro, Tsuneo Tamaki, Hiroshi Fujita

Abstract read
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Masahiro TsukijimaImaging Diagnostic Technology Department, East Nagoya Imaging Diagnosis Center, 3-4-26 Jiyugaoka, Chikusa-ku, Nagoya, Aichi, Japan.
Atsushi TeramotoFaculty of Engineering, Meijo University, Nagoya, Japan. teramoto@fujita-hu.ac.jp.ORCID http://orcid.org/0000-0001-7613-5348
Akihiro KojimaNagoya PET Imaging Center, 1-162 Hokke, Nakagawa-ku, Nagoya, Aichi, Japan.
Osamu YamamuroImaging Diagnostic Technology Department, East Nagoya Imaging Diagnosis Center, 3-4-26 Jiyugaoka, Chikusa-ku, Nagoya, Aichi, Japan.
Tsuneo TamakiImaging Diagnostic Technology Department, East Nagoya Imaging Diagnosis Center, 3-4-26 Jiyugaoka, Chikusa-ku, Nagoya, Aichi, Japan.
Hiroshi FujitaFaculty of Engineering, Gifu University, 1-1 Yanagido, Gifu, Japan.
Nagoya Medical Center · JPFujita Health University Hospital · JPGifu University · JPMeijo University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Dedicated breast positron emission tomography (db-PET) is more sensitive than whole-body positron emission tomography and is thus expected to detect early stage breast cancer and determine treatment efficacy. However, it is challenging to decrease the sensitivity of the chest wall side at the edge of the detector, resulting in a relative increase in noise and a decrease in detectability. Longer acquisition times and injection of larger amounts of tracer improve image quality but increase the burden on the patient. Therefore, this study aimed to improve image quality via reconstruction with shorter acquisition time data using deep learning, which has recently been widely used as a noise reduction technique. In our proposed method, a multi-adaptive denoising filter bank structure was introduced by training the training data separately for each detector area because the noise characteristics of db-PET images vary at different locations. Input and ideal images were reconstructed based on 1- and 7-min collection data, respectively, using list mode data. The deep learning model used residual learning with an encoder-decoder structure. The image quality of the proposed method was superior to that of existing noise reduction filters such as Gaussian filters and nonlocal mean filters. Furthermore, there was no significant difference between the maximum standardized uptake values before and after filtering using the proposed method. Taken together, the proposed method is useful as a noise reduction filter for db-PET images, as it can reduce the patient burden, scan time, and radiotracer amount in db-PET examinations.

Indexed as

BreastPositron-Emission TomographyHumansThoraxDedicated breast PETDeep learningImage processingNoise reduction

Identifiers

PMID37870728
OpenAlexW4387865919

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.