ArticleQuantitative imaging in medicine and surgery2023
Development and evaluation of ultrasound image tracking technology based on Mask R-CNN applied to respiratory motion compensation system.
Article in Quantitative imaging in medicine and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Real-time 3D US-CT fusion-based semi-automatic puncture robot system: clinical evaluation.International journal of computer assisted radiology and surgery · 2025Article
- A study on indirect tumor localization using lung phantom during radiation therapy.Quantitative imaging in medicine and surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: For respiration induced tumor displacement during a radiation therapy, a common method to prevent the extra radiation is image-guided radiation therapy. Moreover, mask region-based convolutional neural networks (Mask R-CNN) is one of the state-of-the-art (SOTA) object detection frameworks capable of conducting object classification, localization, and pixel-level instance segmentation. Methods: We developed a novel ultrasound image tracking technology based on Mask R-CNN for stable tracking of the detected diaphragm motion and applied to the respiratory motion compensation system (RMCS). For training Mask R-CNN, 1800 ultrasonic images of the human diaphragm are collected. Subsequently, an ultrasonic image tracking algorithm was developed to compute the mean pixel coordinates of the diaphragm detected by Mask R-CNN. These calculated coordinates are then utilized by the RMCS for compensation purposes. The tracking similarity verification experiment of mask ultrasonic imaging tracking algorithm (M-UITA) is performed. Results: The correlation between the input signal and the signal tracked by M-UITA was evaluated during the experiment. The average discrete Fréchet distance was less than 4 mm. Subsequently, a respiratory displacement compensation experiment was conducted. The proposed method was compared to UITA, and the compensation rates of three different respiratory signals were calculated and compared. The experimental results showed that the proposed method achieved a 6.22% improvement in compensation rate compared to UITA. Conclusions: This study introduces a novel method called M-UITA, which offers high tracking precision and excellent stability for monitoring diaphragm movement. Additionally, it eliminates the need for manual parameter adjustments during operation, which is an added advantage.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.