ArticleOphthalmology science
Applications of Deep Learning: Automated Assessment of Vascular Tortuosity in Mouse Models of Oxygen-Induced Retinopathy.
Article in Ophthalmology science. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 10 citations in OpenAlex.
- Workflow evaluation of a commercial deep learning-based image analysis tool for the quantification of angiogenesis in vivo.Scientific reports · 2026Article
- Characterization of vascular tortuosity throughout the murine oxygen-induced retinopathy model of ischemic retinopathy.JCI insight · 2026Article
- Review of Retinopathy of Prematurity Management in the Anti-VEGF Era: Evolving Global Paradigms, Persistent Challenges and Our AI-Assisted Future.Clinical & experimental ophthalmology · 2025Review
- Artificial intelligence in retinal image analysis for hypertensive retinopathy diagnosis: a comprehensive review and perspective.Visual computing for industry, biomedicine, and art · 2025Review
- Development of an Open-Source Dataset of Flat-Mounted Images for the Murine Oxygen-Induced Retinopathy Model of Ischemic Retinopathy.Translational vision science & technology · 2024Article
- Review
- Applications of Deep Learning: Automated Assessment of Vascular Tortuosity in Mouse Models of Oxygen-Induced Retinopathy.Ophthalmology scienceArticle
- Automated Quantitative Assessment of Retinal Vascular Tortuosity in Patients with Sickle Cell Disease.Ophthalmology scienceArticle
- Development of a Semi-automated Computer-based Tool for the Quantification of Vascular Tortuosity in the Murine Retina.Ophthalmology scienceArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors at 5 institutions in 2 countries.
Funding
Abstract
Objective: To develop a generative adversarial network (GAN) to segment major blood vessels from retinal flat-mount images from oxygen-induced retinopathy (OIR) and demonstrate the utility of these GAN-generated vessel segmentations in quantifying vascular tortuosity. Design: Development and validation of GAN. Subjects: Three datasets containing 1084, 50, and 20 flat-mount mice retina images with various stains used and ages at sacrifice acquired from previously published manuscripts. Methods: Four graders manually segmented major blood vessels from flat-mount images of retinas from OIR mice. Pix2Pix, a high-resolution GAN, was trained on 984 pairs of raw flat-mount images and manual vessel segmentations and then tested on 100 and 50 image pairs from a held-out and external test set, respectively. GAN-generated and manual vessel segmentations were then used as an input into a previously published algorithm (iROP-Assist) to generate a vascular cumulative tortuosity index (CTI) for 20 image pairs containing mouse eyes treated with aflibercept versus control. Main Outcome Measures: Mean dice coefficients were used to compare segmentation accuracy between the GAN-generated and manually annotated segmentation maps. For the image pairs treated with aflibercept versus control, mean CTIs were also calculated for both GAN-generated and manual vessel maps. Statistical significance was evaluated using Wilcoxon signed-rank tests ( Results: The dice coefficient for the GAN-generated versus manual vessel segmentations was 0.75 ± 0.27 and 0.77 ± 0.17 for the held-out test set and external test set, respectively. The mean CTI generated from the GAN-generated and manual vessel segmentations was 1.12 ± 0.07 versus 1.03 ± 0.02 ( Conclusions: GANs can be used to accurately generate vessel map segmentations from flat-mount images. These vessel maps may be used to evaluate novel metrics of vascular tortuosity in OIR, such as CTI, and have the potential to accelerate research in treatments for ischemic retinopathies. Financial Disclosures: The author(s) have no proprietary or commercial interest in any materials discussed in this article.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.