Laboratory Analysis of Causative Factors for the Final Incision Size due to Intraocular Lens Injector Insertion.

Maximilian Friedrich, Isabella D Baur, Timur M Yildirim, Victor A Augustin, Ramin Khoramnia, Gerd U Auffarth

Open access · goldAbstract read
In one paragraph

Article in Ophthalmology science. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Maximilian FriedrichDepartment of Ophthalmology, The David J Apple International Laboratory for Ocular Pathology, University Hospital Heidelberg, Heidelberg, Germany.
Isabella D BaurDepartment of Ophthalmology, The David J Apple International Laboratory for Ocular Pathology, University Hospital Heidelberg, Heidelberg, Germany.
Timur M YildirimDepartment of Ophthalmology, The David J Apple International Laboratory for Ocular Pathology, University Hospital Heidelberg, Heidelberg, Germany.
Victor A AugustinDepartment of Ophthalmology, The David J Apple International Laboratory for Ocular Pathology, University Hospital Heidelberg, Heidelberg, Germany.
Ramin KhoramniaDepartment of Ophthalmology, The David J Apple International Laboratory for Ocular Pathology, University Hospital Heidelberg, Heidelberg, Germany.
Gerd U AuffarthDepartment of Ophthalmology, The David J Apple International Laboratory for Ocular Pathology, University Hospital Heidelberg, Heidelberg, Germany.
Heidelberg University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: In intraocular lens (IOL) implantation, insertion of the IOL injector enlarges the clear corneal incision. A larger incision size (IS) is associated with a higher risk for surgically induced astigmatism and endophthalmitis. The goal of this study was to determine which parameters most influence the final IS. Design: Experimental study. Subjects: A total of 126 cadaver porcine eyes were included in this study. Methods: We analyzed 409 clear corneal incisions made with 126 injectors from 13 injector models. We noted the vertical diameter and the tip angulation for every model. The corneal thickness of each incision location was measured using Scheimpflug tomography. The IS was measured before and after injector insertion and described as preoperative and final ISs, respectively. During surgery, the insertion depth and incision length were documented. A mixed effects model was applied to analyze the influence of the parameters on the final IS. Main Outcome Measures: Influence on the final IS. Results: Increases in the vertical diameter of the injector tip, the preoperative IS and the insertion depth, and a reduction of incision length were all significantly associated with increased final IS ( Conclusions: The IOL injector's vertical diameter should be as small as possible to ensure a minimal final IS. The injector's insertion depth may be minimized, and the incision length should be long enough to reduce the final IS. Further studies are needed to confirm the findings in human autopsy eyes and in clinical practice. Financial Disclosures: Proprietary or commercial disclosure may be found after the references in the Footnotes and Disclosures at the end of this article..

Indexed as

DiameterIncision lengthIncision sizeInsertion depthIntraocular lens injector

Identifiers

PMID37869017
PMCPMC10587621
OpenAlexW4381988823

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.