Evidence map›Paper›PMID 37868361›Full record

ArticleACS measurement science au2023

Disposable Device for Bacterial Vaginosis Detection.

Mariana D Avila-Huerta, Karina Leyva-Hidalgo, Karen Cortés-Sarabia, Ana K Estrada-Moreno, Amalia Vences-Velázquez, Eden Morales-Narváez

Open access · goldAbstract read
In one paragraph

Article in ACS measurement science au, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Mariana D Avila-HuertaCentro de Investigaciones en Óptica, A. C., Loma del Bosque 115, Lomas del Campestre, León 37150, Guanajuato, Mexico.
Karina Leyva-HidalgoCentro de Investigaciones en Óptica, A. C., Loma del Bosque 115, Lomas del Campestre, León 37150, Guanajuato, Mexico.
Karen Cortés-SarabiaFacultad de Ciencias Químico Biológicas, Universidad Autónoma de Guerrero, Chilpancingo 39070, Guerrero, Mexico.
Ana K Estrada-MorenoFacultad de Ciencias Químico Biológicas, Universidad Autónoma de Guerrero, Chilpancingo 39070, Guerrero, Mexico.
Amalia Vences-VelázquezFacultad de Ciencias Químico Biológicas, Universidad Autónoma de Guerrero, Chilpancingo 39070, Guerrero, Mexico.
Eden Morales-NarváezCentro de Investigaciones en Óptica, A. C., Loma del Bosque 115, Lomas del Campestre, León 37150, Guanajuato, Mexico.ORCID https://orcid.org/0000-0002-1536-825X
Centro de Investigaciones en Optica · MXUniversidad Autónoma de Guerrero · MX

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Due to the increasing demand for clinical testing of infectious diseases at the point-of-care, the global market claims alternatives for rapid diagnosis tools such as disposable biosensors, avoiding the need for specialized laboratories and skilled personnel. Bacterial vaginosis (BV) is an infectious disease that commonly affects reproductive-age women and predisposes the infection of sexually transmitted diseases. Especially in asymptomatic cases, BV can lead to pelvic inflammatory conditions, postpartum endometritis, and preterm labor. Conventionally, BV diagnosis involves the microscopic analysis of vaginal swab samples; it thus requires highly trained personnel. In response, we report a novel microfluidic paper-based analytical device for BV diagnosis. Sialidase, a biomarker overexpressed in BV, was detected by exploiting an immunosensing mechanism previously discovered by our team. This technology employs a graphene oxide-coated surface as a quencher of fluorescence; the fluorescence of the immunoprobes that do not experiment immunoreactions (antibody-antigen) are deactivated by graphene oxide via non-radiative energy transfer, whereas those immunoprobes undergoing immunoreactions preserve their photoluminescence due to the distance and the low affinity between the immunocomplex and the graphene oxide-coated surface. Our paper-based test was typically carried out within 20 min, and the sample volume was 6 μL. Besides, it was tested with 14 vaginal swabs specimens to discriminate clinical samples of women with normal microbiota from those with BV. Our disposable device represents a new tool to prevent the consequences of BV.

Identifiers

PMID37868361
PMCPMC10588930
OpenAlexW4381094017

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.