Evidence map›Paper›PMID 37867232›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2023

Tailored Microcantilever Optimization for Multifrequency Force Microscopy.

Gourav Bhattacharya, Indrianita Lionadi, Andrew Stevenson, Joanna Ward, Amir Farokh Payam

Open access · goldAbstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. Incongruous Harmonics of Vibrating Solid-Solid Interface.Small (Weinheim an der Bergstrasse, Germany) · 2025
    Article
  3. Nonlinear Harmonics: A Gateway to Enhanced Image Contrast and Material Discrimination.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
  4. Article
  5. Tailored Microcantilever Optimization for Multifrequency Force Microscopy.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Gourav BhattacharyaNanotechnology and Integrated Bioengineering Centre (NIBEC), School of Engineering, Ulster University, Belfast, BT15 1AP, UK.ORCID https://orcid.org/0000-0001-5235-9240
Indrianita LionadiNanotechnology and Integrated Bioengineering Centre (NIBEC), School of Engineering, Ulster University, Belfast, BT15 1AP, UK.
Andrew StevensonNanotechnology and Integrated Bioengineering Centre (NIBEC), School of Engineering, Ulster University, Belfast, BT15 1AP, UK.
Joanna WardNanotechnology and Integrated Bioengineering Centre (NIBEC), School of Engineering, Ulster University, Belfast, BT15 1AP, UK.ORCID https://orcid.org/0000-0002-1659-7484
Amir Farokh PayamNanotechnology and Integrated Bioengineering Centre (NIBEC), School of Engineering, Ulster University, Belfast, BT15 1AP, UK.ORCID https://orcid.org/0000-0002-6433-2261
University of Ulster · GB

Funding

Department for the Economy (DfE), Northern Ireland USI 186
6 · The paper itself

Abstract

Microcantilevers are at the heart of atomic force microscopy (AFM) and play a significant role in AFM-based techniques. Recent advancements in multifrequency AFM require the simultaneous excitation and detection of multiple eigenfrequencies of microcantilevers to assess more data channels to quantify the material properties. However, to achieve higher spatiotemporal resolution there is a need to optimize the structure of microcantilevers. In this study, the architecture of the cantilever with gold nanoparticles using a dip-coating method is modified, aiming to tune the higher eigenmodes of the microcantilever as integer multiples of its fundamental frequency. Through the theoretical methodology and simulative model, that integer harmonics improve the coupling in multifrequency AFM measurements is demonstrated, leading to enhanced image quality and resolution. Furthermore, via the combined theoretical-experimental approach, the interplay between induced mass and stiffness change of the modified cantilever depending on the attached particle location, size, mass, and geometry is found. To validate the results of this predictive model, tapping-mode AFM is utilized and bimodal Amplitude Modulation AFM techniques to examine and quantify the impact of tuning higher-order eigenmodes on the imaging quality of a polystyrene-polymethylmethacrylate (PS-PMMA) block co-polymer assembly deposited on a glass slide and Highly Ordered Pyrolytic Graphite (HOPG).

Indexed as

atomic force microscopydip-coatingeigenfrequencyharmonicsmicrocantilever

Identifiers

PMID37867232
PMCPMC10667852
OpenAlexW4387865930

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.