Evidence map›Paper›PMID 37864121›Full record

ArticleCardiology and therapy2023

Comparative Effectiveness of Various Radiofrequency Ablation Catheters in the Ablation of Typical Atrial Flutter.

Asher Gorantla, Mahmoud Alsaiqali, Jonathan Francois, Shruthi Sivakumar, Leonell Freytes-Santiago, Ahmad Jallad, Adam S Budzikowski

Abstract read
In one paragraph

Article in Cardiology and therapy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Asher GorantlaDepartment of Medicine, SUNY Health Sciences University, Brooklyn, NY, USA.
Mahmoud AlsaiqaliDepartment of Medicine, SUNY Health Sciences University, Brooklyn, NY, USA.
Jonathan FrancoisDivision of Cardiovascular Medicine-EP Section, SUNY Health Sciences University, 450 Clarkson Ave, Box 1199, Brooklyn, NY, 11203, USA.
Shruthi SivakumarDepartment of Medicine, SUNY Health Sciences University, Brooklyn, NY, USA.
Leonell Freytes-SantiagoDivision of Cardiovascular Medicine-EP Section, SUNY Health Sciences University, 450 Clarkson Ave, Box 1199, Brooklyn, NY, 11203, USA.
Ahmad JalladDivision of Cardiovascular Medicine-EP Section, SUNY Health Sciences University, 450 Clarkson Ave, Box 1199, Brooklyn, NY, 11203, USA.
Adam S BudzikowskiDivision of Cardiovascular Medicine-EP Section, SUNY Health Sciences University, 450 Clarkson Ave, Box 1199, Brooklyn, NY, 11203, USA. abudzikowski@downstate.edu.ORCID http://orcid.org/0000-0003-0179-3930

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAlthough ablation of typical atrial flutter (AFL) can be easily achieved with radiofrequency energy (RF), no studies compare the effectiveness of different ablation catheters. Our study aimed to compare the efficacy of various types of ablation catheters in treating typical AFL.

methodsWe analyzed patients with AFL who underwent RF ablation by a single operator at our institution. Successful ablation was evidenced by a bidirectional conduction block (trans-isthmus conduction time ≥ 130 ms or double potentials ≥ 90 ms). Logistic regression was used to compare success rate and linear regression to compare lesion time.

resultsOut of 222 patients, only six did not meet the success criteria (2.7%). The catheters used were non-irrigated, large-tip, internally irrigated (Chili II Boston Scientific), and externally irrigated (non-force-sensing) catheters (Cool Path, Abbott). An externally irrigated force-sensing catheter (TactiCath, Abbott) was used with > 10 gm of force and (LPLD) setting (30 W- 45 °C- 60 s), and high-power short-duration (HPSD) setting (50 W- 43 °C - 12 s). No complications were encountered. The catheter type had no statistically significant association with ablation success. With the use of externally irrigated catheter with contract force-sensing and HPSD settings, statistically significantly shortening of lesion time was achieved 758.3 s, [CI - 1128.29, - 388.35 s] followed by LPLD by 419.0 s [CI - 808.49, - 29.47 s].

conclusionsThe typical atrial flutter radiofrequency ablation procedure had a high success rate, which was not influenced by the type of ablation catheter. Contact force ablation catheter and HPSD are associated with shorter total lesion time.

Indexed as

AblationAtrial flutterForce sensingIrrigated catheter

Identifiers

PMID37864121
PMCPMC10703754

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.