Evidence map›Paper›PMID 37860939›Full record

ArticleJournal of synchrotron radiation2023

The new small-angle X-ray scattering beamline for materials research at PETRA III: SAXSMAT beamline P62.

S Haas, X Sun, A L C Conceição, J Horbach, S Pfeffer

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

S HaasDeutsches Elektronen-Synchrotron (DESY), Notkestrasse 85, Hamburg 22607, Germany.ORCID 0000-0001-7066-0205
X SunDeutsches Elektronen-Synchrotron (DESY), Notkestrasse 85, Hamburg 22607, Germany.ORCID 0000-0001-5428-3526
A L C ConceiçãoDeutsches Elektronen-Synchrotron (DESY), Notkestrasse 85, Hamburg 22607, Germany.
J HorbachDeutsches Elektronen-Synchrotron (DESY), Notkestrasse 85, Hamburg 22607, Germany.
S PfefferDeutsches Elektronen-Synchrotron (DESY), Notkestrasse 85, Hamburg 22607, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The SAXSMAT beamline P62 (Small-Angle X-ray Scattering beamline for Materials Research) is a new beamline at the high-energy storage ring PETRA III at DESY. This beamline is dedicated to combined small- and wide-angle X-ray scattering (SAXS/WAXS) techniques for both soft and hard condensed matter systems. It works mainly in transmission geometry. The beamline covers an energy range from 3.5 keV to 35.0 keV, which fulfills the requirements of the user community to perform anomalous scattering experiments. Mirrors are used to reduce the intensity of higher harmonics. Furthermore, the mirrors and 2D compound refracting lenses can focus the beam down to a few micrometres at the sample position. This option with the high photon flux enables also SAXS/WAXS tensor tomography experiments to be performed at this new beamline in a relatively short time. The first SAXS/WAXS pattern was collected in August 2021, while the first user experiment was carried out two months later. Since January 2022 the beamline has been in regular user operation mode. In this paper the beamline optics and the SAXS/WAXS instrument are described and two examples are briefly shown.

Indexed as

anomalous scatteringASAXScomputed tomographySAXSSAXS-CTSAXS tensor tomographySAXS-TTWAXS

Identifiers

PMID37860939
PMCPMC10624033

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.