Evidence map›Paper›PMID 37860561›Full record

ArticleHeliyon2023

Usefulness of a drill stopper to prevent iatrogenic soft tissue injury in orthopedic surgery.

Jung Hwan Choi, Young Seok Lee, Kyu-Tae Hwang, Young-Hoon Jo, Hyun Sik Shin, Jihwan Kim, Ki-Chul Park

Abstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jung Hwan ChoiDepartment of Orthopaedic Surgery, Hanyang University Guri Hospital, Guri, Republic of Korea.
Young Seok LeeDepartment of Orthopaedic Surgery, Hanyang University Guri Hospital, Guri, Republic of Korea.
Kyu-Tae HwangDepartment of Orthopaedic Surgery, Hanyang University Hospital, Seoul, Republic of Korea.
Young-Hoon JoDepartment of Orthopaedic Surgery, Hanyang University Guri Hospital, Guri, Republic of Korea.
Hyun Sik ShinDepartment of Orthopaedic Surgery, Hanyang University Hospital, Seoul, Republic of Korea.
Jihwan KimDepartment of Orthopaedic Surgery, Hanyang University Guri Hospital, Guri, Republic of Korea.
Ki-Chul ParkDepartment of Orthopaedic Surgery, Hanyang University Guri Hospital, Guri, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: This study introduces a novel technique utilizing a drill stopper to limit drill penetration depth and to prevent iatrogenic injuries, specifically neurovascular damage, in orthopedic surgeries. Orthopedic surgeries frequently involve the use of drills, which are essential tools for various procedures. However, improper handling of drills can lead to iatrogenic soft tissue injuries, causing severe consequences such as permanent disability or life-threatening complications. To address this issue, we propose the use of a drill stopper as a safeguard to prevent excessive drill penetration and reduce the risk of soft tissue damage during surgery. Materials and Methods: The study involved 32 orthopedic surgeons, half of whom were experienced and the other half inexperienced. Synthetic femur bone models (Synbone) were used for drilling exercises, employing four configurations: a sharp drill bit without a stopper (SF, Sharp Free), a sharp drill bit with a stopper (SS, Sharp Stopper), a blunt drill bit without a stopper (BF, Blunt Free), and a blunt drill bit with a stopper (BS, Blunt Stopper). Each participant conducted three trials for each configuration, and the penetration depth was measured after each trial. Results: For experienced surgeons, the average penetration depths were 3.83 (±1.826)mm for SF, 11.02 (±3.461)mm for BF, 2.88 (±0.334)mm for SS, and 2.75 (±0.601)mm for BS. In contrast, inexperienced surgeons had average depths of 8.52 (±4.608)mm for SF, 18.75 (±4.305)mm for BF, 2.96 (±0.683)mm for SS, and 2.83 (±0.724)mm for BS. Conclusion: The use of a drill stopper was highly effective in controlling drill penetration depth and preventing iatrogenic injuries during orthopedic surgeries. We recommend its incorporation, particularly when using a blunt drill bit or when an inexperienced surgeon operates in an anatomically unfamiliar area. Using the drill stopper, the risk of severe injuries from excessive drill penetration can be minimized, leading to improved patient safety and better surgical outcomes.

Identifiers

PMID37860561
PMCPMC10582358

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.