Feasibility of new patient dose management tool in digital radiography: Using clinical exposure index data of mobile chest radiography in a large university hospital.

Hyemin Park, Jungsu Kim, Eun-Ju Kang, Yeji Kim, Hyejin Jo, Jin-Haeng Heo, Wonseok Yang, Yongsu Yoon

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 4 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Hyemin ParkDepartment of Radiology, Masan University, Changwon, Republic of Korea.
Jungsu KimDepartment of Radiologic Technology, Daegu Health College, Daegu, Republic of Korea.
Eun-Ju KangDepartment of Radiology, Dong-A University Hospital, Busan, Republic of Korea.
Yeji KimDepartment of Multidisciplinary Radiological Science, The Graduate School of Dongseo University, Busan, Republic of Korea.
Hyejin JoDepartment of Multidisciplinary Radiological Science, The Graduate School of Dongseo University, Busan, Republic of Korea.
Jin-Haeng HeoDepartment of Multidisciplinary Radiological Science, The Graduate School of Dongseo University, Busan, Republic of Korea.
Wonseok YangDepartment of Radiology, Dong-A University Hospital, Busan, Republic of Korea.
Yongsu YoonDepartment of Multidisciplinary Radiological Science, The Graduate School of Dongseo University, Busan, Republic of Korea.
Dongseo University · KRDong-A University Hospital · KRDaegu Health College · KRMasan University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The clinical anteroposterior (AP) chest images taken with a mobile radiography system were analyzed in this study to utilize the clinical exposure index (EI) as a patient dose-monitoring tool. The digital imaging and communications in medicine header of 6048 data points exposed under the 90 kVp and 2.5 mAs were extracted using Python for identifying the distribution of clinical EI. Even under the same exposure conditions, the clinical EI distribution was 137.82-4924.38. To determine the cause, the effect of a patient's body shape on EI was confirmed using actual clinical chest AP image data binarized into 0 and 255-pixel values using Python. As a result, the relationship between the direct X-ray area of the chest AP image, the higher the clinical EI, the larger the rate of the direct X-ray area. A conversion equation was also derived to infer entrance surface dose through clinical EI based on the patient thickness. This confirmed the possibility of directly monitoring patient dose through EI without a dosimeter in real-time. Therefore, to use the clinical EI of the mobile radiography system as a patient dose-monitoring tool, the derivation method of clinical EI considers several factors, such as the relationship between patient factors.

Indexed as

Dose managementExposure indexGeneral radiographyOptimizationPatient dose

Identifiers

PMID37860502
PMCPMC10582475
OpenAlexW4387424246

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.