Evidence map›Paper›PMID 37858210›Full record

ArticleBMC ophthalmology2023

Recanalization of Xen45 gel stent implant occlusion using 10 - 0 nylon suture in refractory glaucoma: a case report.

Yao Zhang, Haotian Xiang, Yangyang Zhang, Li Tang

Open access · goldAbstract readCase Reports
In one paragraph

Article in BMC ophthalmology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Review
  5. How to Rescue of the Dislocated XENJournal of current ophthalmology
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Yao Zhang *Department of Ophthalmology, West China Hospital of Sichuan University, Chengdu, China.
Haotian Xiang *Department of Ophthalmology, West China Hospital of Sichuan University, Chengdu, China.
Yangyang ZhangDepartment of Ophthalmology, West China Hospital of Sichuan University, Chengdu, China.
Li TangDepartment of Ophthalmology, West China Hospital of Sichuan University, Chengdu, China. tangli-1a@wchscu.cn.
Sichuan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundXen Gel Stent implant is a new minimally invasive surgical treatment for glaucoma that has been proven effectiveness and safety profile. However, it may also lead to some complications. Xen Gel Stent occlusion is a relatively rare complication reported less frequently and has limited treatment experience. In our case report, we proposed a novel surgical treatment using a 10 - 0 nylon suture to successfully recanalize the occluded Xen45 Gel Stent. CASE PRESENTATION: A 16-year-old female patient had bilateral juvenile glaucoma for the past 5 years. Her right eye had undergone three glaucoma surgeries but failed. At a presentation to our hospital, the right eye's intraocular pressure (IOP) was 30 mmHg despite applying four different active principles. Xen45 Gel Stent implant was chosen for treatment, but six days after implantation, the IOP rose to 40 mmHg as a result of an anterior chamber tip occlusion of the Xen45 Gel Stent. Nd: YAG laser shockwave therapy was attempted but failed. The patient eventually had to return to the operating room for a revision procedure. The Xen45 Gel Stent was recanalized from the ab externo by making an L-shaped conjunctival incision at the fornix base and threading a 10 - 0 nylon suture through it. The IOP was successfully controlled in the 11-month follow-up without medication.

conclusionIf postoperative occlusion arises after Xen45 Gel Stent implantation, surgery using 10 - 0 nylon suture to recanalize Xen45 Gel Stent should be considered as a relatively safe, effective that does not require removal of Xen45 Gel Stent.

Indexed as

GlaucomaGlaucoma Drainage ImplantsAdolescentFemaleHumansIntraocular PressureNylonsStentsSuturesTreatment OutcomeNylonsGlaucomaMicro-invasive glaucoma surgeryOcclusionPostoperative complicationsRecanalizationXen gel stent

Identifiers

PMID37858210
PMCPMC10585744
OpenAlexW4387779092

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.