Evidence map›Paper›PMID 37854960›Full record

ArticlePostepy w kardiologii interwencyjnej = Advances in interventional cardiology2023

3D printing from transesophageal echocardiography for planning mitral paravalvular leak closure - feasibility study.

Marek Jędrzejek, Ewa Peszek-Przybyła, Tomasz Jadczyk, Jakub Zemik, Paulina Piprek, Piotr Pysz, Michał Kozłowski, Wojciech Wojakowski, Grzegorz Smolka

Open access · goldAbstract read
In one paragraph

Article in Postepy w kardiologii interwencyjnej = Advances in interventional cardiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Review
  3. From bench to bedside and back: translational cardiovascular interventions in veterinary medicine.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2025
    Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Marek JędrzejekDepartment of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland.
Ewa Peszek-PrzybyłaDepartment of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland.
Tomasz JadczykDepartment of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland.
Jakub ZemikFaculty of Sciences and Technology, University of Silesia, Katowice, Poland.
Paulina PiprekDoctoral School, Medical University of Silesia, Katowice, Poland.
Piotr PyszDepartment of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland.
Michał KozłowskiDepartment of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland.
Wojciech WojakowskiDepartment of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland.
Grzegorz SmolkaDepartment of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland.
Medical University of Silesia · PLUniversity of Silesia in Katowice · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Transcatheter closure of paravalvular leak (PVL) is still a demanding procedure due to the complex anatomy of PVL channels and risk of interference between the implanted occluder and surrounding structures. Efforts are made to improve procedural outcomes in transcatheter structural heart interventions by establishing treatment strategy in advance with the use of 3D-printed physical models based on data obtained from cardiac computed tomography (CT) studies. Aim: In this feasibility study 3D printing of PVL models based on data recorded during transesophageal echocardiography (TEE) examinations was evaluated. Material and methods: 3D-TEE data of patients with significant PVL around mitral valve prostheses were used to prepare 3D models. QLab software was used to export DICOM images in Cartesian DICOM format of each PVL with the surrounding tissue. Image segmentation was performed in Slicer, a free, open-source software package used for imaging research. Models were printed to actual size with the Polyjet printer with a transparent, rigid material. We measured dimensions of PVLs both in TEE recordings and printed 3D models. The results were correlated with sizes of occluding devices used to close the defects. Results: In 7 out of 8 patients, there was concordance between procedurally implanted occluders and pre-procedurally matched closing devices based on 3D-printed models. Conclusions: 3D-printing from 3D-TEE is technically feasible. Both shape and location of PVLs are preserved during model preparation and printing. It remains to be tested whether 3D printing would improve outcomes of percutaneous PVL closure.

Indexed as

3D printingechocardiographymitral valveparavalvular leakslicer

Identifiers

PMID37854960
PMCPMC10580856
OpenAlexW4387110645

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.