Evidence map›Paper›PMID 37854472›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2023

Revealing pelvic structures in the presence of metal hip prothesis via non-circular CBCT orbits.

Tess Reynolds, Yiqun Ma, Tianyu Wang, Kai Mei, Peter B Noël, Grace J Gang, J Webster Stayman

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Tess ReynoldsThe University of Sydney, Australia.
Yiqun MaJohns Hopkins University, United States of America.
Tianyu WangJohns Hopkins University, United States of America.
Kai MeiUniversity of Pennsylvania, United States of America.
Peter B NoëlUniversity of Pennsylvania, United States of America.
Grace J GangJohns Hopkins University, United States of America.
J Webster StaymanJohns Hopkins University, United States of America.
California University of Pennsylvania · USJohns Hopkins University · USUniversity of Sydney · AU

Funding

Task-Driven 3D Interventional ImagingR01EB027127 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI STAYMAN, JOSEPH WEBSTER · 2019 to 2022
$1.8M
NIBIB NIH HHS R01 EB027127
6 · The paper itself

Abstract

As the expansion of Cone Beam CT (CBCT) to new interventional procedures continues, the burdensome challenge of metal artifacts remains. Photon starvation and beam hardening from metallic implants and surgical tools in the field of view can result in the anatomy of interest being partially or fully obscured by imaging artifacts. Leveraging the flexibility of modern robotic CBCT imaging systems, implementing non-circular orbits designed for reducing metal artifacts by ensuring data-completeness during acquisition has become a reality. Here, we investigate using non-circular orbits to reduce metal artifacts arising from metallic hip prostheses when imaging pelvic anatomy. As a first proof-of-concept, we implement a sinusoidal and a double-circle-arc orbit on a CBCT test bench, imaging a physical pelvis phantom, with two metal hip prostheses, housing a 3D-printed iodine-filled radial line-pair target. A standard circular orbit implemented with the CBCT test bench acted as comparator. Imaging data collection and processing, geometric calibration and image reconstruction was completed using in-house developed software programs. Imaging with the standard circular orbit, image artifacts were observed in the pelvic bones and only 33 out of the possible 45 line-pairs of the radial line-pair target were partially resolvable in the reconstructed images. Comparatively, imaging with both the sinusoid and double-circle-arc orbits reduced artifacts in the surrounding anatomy and enabled all 45 line-pairs to be visibly resolved in the reconstructed images. These results indicate the potential of non-circular orbits to assist in revealing previously obstructed structures in the pelvic region in the presence of metal hip prosthesis.

Indexed as

3D-printingCBCTmetal artifactsnon-circular orbits

Identifiers

PMID37854472
PMCPMC10583095
OpenAlexW4362487517

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked