Evidence map›Paper›PMID 37853479›Full record

ArticleJournal of orthopaedic surgery and research2023

The effect of femoral prosthesis design on patellofemoral contact stresses in total knee arthroplasty: a case-control study with mid-term follow-up minimum 3-year follow-up.

Lingce Kong, Wei Lin, Huijun Kang, Ming Li, Kuo Hao, Bo Chang, Fei Wang

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Does patellar resurfacing matter in robotic-assisted total knee arthroplasty with functional alignment principles?Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025
    Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Lingce Kong *Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, China.
Wei Lin *Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, China.
Huijun KangDepartment of Orthopedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, China.
Ming LiDepartment of Orthopedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, China.
Kuo HaoDepartment of Orthopedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, China.
Bo ChangDepartment of Orthopedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, China.
Fei WangDepartment of Orthopedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, China. doctorwfei@163.com.
Hebei Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo investigate the differences in postoperative patellofemoral pressures and patellar tracking during at least three years of follow-up in patients using three prostheses of different designs in total knee arthroplasty (TKA) without patellar resurfacing.

methodsRADIOGRAPHIC INVESTIGATIONS: The study included 401 patients who had a total of 480 knee prostheses implanted without patellar resurfacing. The prostheses used were Genesis II (external rotation design of femoral prosthesis), Triathlon (design with deep trochlear grooves), and Gemini MK II (deepening of trochlear groove and lateral condylar protrusion that closely follows the anatomical shape). The patients' patellar tracking was assessed by measuring patellar tilt and displacement during postoperative follow-up. Furthermore, postoperative knee function and pain were evaluated through range of motion, Knee Society scores (KSS), and Forgotten Joint Score (FJS) to compare the different groups. FINITE ELEMENT ANALYSIS: Constructing a finite element model of the knee joint of a normal volunteer after total knee arthroplasty using different prostheses for nonpatellar replacement. The three models' von Mises stress distribution heat map, peak contact pressure, and patellar transverse displacement were compared at 30°, 60°, and 90°, respectively.

resultsRADIOGRAPHIC INVESTIGATIONS: A total of 456 knees of 384 patients were investigated at a 3-year follow-up after TKA without patellar resurfacing. There were no significant differences in patellar tracking between the three groups. Patients with all three prostheses demonstrated favorable clinical outcomes at 3 years postoperatively, with no statistically significant differences in knee scores (91.9 vs 92.3 vs 91.8) or range of motion (127.9° vs 128.5° vs 127.7°) between the groups. However, there was a significant difference between Genesis II and Gemini MK II in the Forgotten Joint Score (59.7 vs 62.4). Patients with persistent postoperative anterior knee pain were present in all three groups (16 vs 12 vs 10), but the incidence was not significantly different. FINITE ELEMENT ANALYSIS: The von Mises stress distribution heat map showed that during flexion, the patellofemoral stresses were mainly concentrated on the lateral side of the prosthesis side, and the contact site gradually shifted downward with increasing flexion angle. At the same time, the peak contact stress of the patellofemoral joint increased with the gradual increase in the flexion angle. Genesis II, with a wider and shallower trochlear groove, showed greater patellofemoral stresses and lateral patellar displacement after TKA without patellar resurfacing. The Gemini MK II with a deeper trochlear groove and slightly protruding lateral condyle is more in line with anatomical design, with smaller patellofemoral joint pressure and better patellar tracking.

conclusionsIn TKA without patellar resurfacing, a prosthesis with a deeper trochlear groove, a slightly higher lateral femoral condyle, and a more anatomically designed knee that better matches the patellar morphology should be a better choice.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisPatellofemoral JointCase-Control StudiesFollow-Up StudiesHumansKnee JointPainPatellaProsthesis DesignRange of Motion, ArticularFinite elementPatellofemoral jointTotal knee arthroplasty

Identifiers

PMID37853479
PMCPMC10583349
OpenAlexW4387739860

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked