Evidence map›Paper›PMID 37853424›Full record

ArticleBMC veterinary research2023

Intra-aortic band impairs transapical device implantation in a pig: a case report.

Florian Meissner, Michelle Costa Galbas, Johannes Dinkelaker, Heidi Cristina Schmitz, Hendrik Straky, Johanna Reuter, Martin Czerny, Wolfgang Bothe

Open access · goldAbstract readCase Reports
In one paragraph

Article in BMC veterinary research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Florian MeissnerDepartment of Cardiovascular Surgery, University Heart Center Freiburg, Hugstetter Strasse 55, 79106, Freiburg, Germany. florian.meissner@uniklinik-freiburg.de.
Michelle Costa GalbasDepartment of Cardiovascular Surgery, University Heart Center Freiburg, Hugstetter Strasse 55, 79106, Freiburg, Germany.
Johannes DinkelakerCenter for Experimental Models and Transgenic Service, Faculty of Medicine, University of Freiburg, Stefan-Meier-Strasse 17, 79104, Freiburg, Germany.
Heidi Cristina SchmitzCenter for Experimental Models and Transgenic Service, Faculty of Medicine, University of Freiburg, Stefan-Meier-Strasse 17, 79104, Freiburg, Germany.
Hendrik StrakyDepartment of Cardiovascular Surgery, University Heart Center Freiburg, Hugstetter Strasse 55, 79106, Freiburg, Germany.
Johanna ReuterDepartment of Cardiovascular Surgery, University Heart Center Freiburg, Hugstetter Strasse 55, 79106, Freiburg, Germany.
Martin CzernyDepartment of Cardiovascular Surgery, University Heart Center Freiburg, Hugstetter Strasse 55, 79106, Freiburg, Germany.
Wolfgang BotheDepartment of Cardiovascular Surgery, University Heart Center Freiburg, Hugstetter Strasse 55, 79106, Freiburg, Germany.
Universitäts-Herzzentrum Freiburg-Bad Krozingen · DEUniversity of Freiburg · DEUniversity Medical Center Freiburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAnatomic anomalies in the ascending aorta may impair the implantation and testing of cardiovascular devices in humans and animal models. CASE PRESENTATION: We present the rare case of an intra-aortic band in a German Landrace pig. During terminal animal testing, the band hindered the implantation of a left ventricular assist device (LVAD) with transventricular outflow graft across the aortic valve. After lower partial sternotomy, epicardial echocardiography displayed an intraluminal echogenic structure at the sinotubular junction causing unspecific flow turbulences. Under cardiopulmonary bypass, coring of the left ventricular apex was performed. Due to strong resistance in the proximal aorta, accurate positioning of the transventricular LVAD outflow graft was impossible. After euthanasia, necropsy revealed a fibrous band located at the sinotubular junction, dividing the lumen of the ascending aorta.

conclusionsThe occurrence of an intra-aortic band represents an extremely rare case of a most likely congenital anomaly. Awareness of such anomalies is important for planning and performing animal testing. Perioperative echocardiography may help to either remove such anomalies or allow discontinuing the procedure prior to device implantation.

Indexed as

Aortic Valve InsufficiencySwine DiseasesAnimalsAortaAorta, ThoracicEuthanasia, AnimalHumansModels, AnimalSwineAnimal testingCongenital anomaliesEndovascular proceduresIntra-aortic bandLeft ventricular assist devicePig

Identifiers

PMID37853424
PMCPMC10583487
OpenAlexW4387741828

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.