ArticleScience advances2023
A self-assembled implantable microtubular pacemaker for wireless cardiac electrotherapy.
Article in Science advances, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 57 citations in OpenAlex.
- Intratumoral therapeutic dust for chemo-photodynamic combination treatment.Science advances · 2026Article
- Self-sustaining leadless intracardiac pacemaker powered by triboelectric nanogenerator.Science advances · 2026Article
- 3D-printed implantable bioelectronics enabled by anti-swelling and biphasic conductive hydrogels.Nature materials · 2026Article
- Ultra-flexible optoelectronic stimulator converts tissue-attenuated weak light into electrical signals for cardiac remodeling.Nature communications · 2026Article
- Self-powered intelligence for personalized healthcare.National science review · 2026Review
- Reversible Thermoactuation Unlocks Minimally Invasive Implantation and Retrieval of Soft Bioelectronics.Advanced materials (Deerfield Beach, Fla.) · 2026Article
- Toward a fully wireless endovascular neural interface: Evaluating power transfer efficacy.PloS one · 2026Article
- Metasurface-assisted bioelectronics: bridging photonic innovation with biomedical implants.Light, science & applications · 2025Article
- NFC/RFID-enabled wearables and implants for biomedical applications.Microsystems & nanoengineering · 2025Review
- A Hydro-Expansive and Degradable Biomaterial Enabling Shape Recovery of Film-Based Devices in Biofluids.Advanced materials (Deerfield Beach, Fla.) · 2025Article
- Article
- Machine learning-assisted point-of-care diagnostics for cardiovascular healthcare.Bioengineering & translational medicine · 2025Review
- Instantaneous Piezoelectric Nanogenerator for Pacemaker Applications.Nano energy · 2025Article
- Novel Electroactive Therapeutic Platforms for Cardiac Arrhythmia Management.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Review
- Advances in 2D materials for wearable biomonitoring.Materials science & engineering. R, Reports : a review journal · 2025Article
- Article
- Unleashing the Potential of Electroactive Hybrid Biomaterials and Self-Powered Systems for Bone Therapeutics.Nano-micro letters · 2024Review
- Frontiers in artificial intelligence-directed light-sheet microscopy for uncovering biological phenomena and multi-organ imaging.View (Beijing, China) · 2024Article
- Triboelectric nanogenerators for self-powered neurostimulation.Nano research · 2024Article
- Advances in piezoelectric nanogenerators for self-powered cardiac care.Nano trends (2023) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors at 1 institution in 1 country.
Funding
Abstract
The current cardiac pacemakers are battery dependent, and the pacing leads are prone to introduce valve damage and infection, plus a complete pacemaker retrieval is needed for battery replacement. Despite the reported wireless bioelectronics to pace the epicardium, open-chest surgery (thoracotomy) is required to implant the device, and the procedure is invasive, requiring prolonged wound healing and health care burden. We hereby demonstrate a fully biocompatible wireless microelectronics with a self-assembled design that can be rolled into a lightweight microtubular pacemaker for intravascular implantation and pacing. The radio frequency was used to transfer energy to the microtubular pacemaker for electrical stimulation. We show that this pacemaker provides effective pacing to restore cardiac contraction from a nonbeating heart and have the capacity to perform overdrive pacing to augment blood circulation in an anesthetized pig model. Thus, this microtubular pacemaker paves the way for the minimally invasive implantation of leadless and battery-free microelectronics.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.