Evidence map›Paper›PMID 37848329›Full record

ArticleZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery2023

[Research progress in influence of microstructure on performance of triply-periodic minimal surface bone scaffolds].

Yadi Sun, Jianxiong Ma, Yan Wang, Benchao Dong, Peichuan Yang, Yan Li, Yiyang Li, Liyun Zhou, Jiahui Shen, Xinlong Ma

Abstract readEnglish Abstract
In one paragraph

Article in Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. [Study on NaOH improving the surface morphology of three-dimensional printed poly-Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Yadi SunInstitute of Orthopaedics, Tianjin Hospital, Tianjin University (Tianjin Hospital), Tianjin, 300211, P. R. China.
Jianxiong MaInstitute of Orthopaedics, Tianjin Hospital, Tianjin University (Tianjin Hospital), Tianjin, 300211, P. R. China.
Yan WangInstitute of Orthopaedics, Tianjin Hospital, Tianjin University (Tianjin Hospital), Tianjin, 300211, P. R. China.
Benchao DongInstitute of Orthopaedics, Tianjin Hospital, Tianjin University (Tianjin Hospital), Tianjin, 300211, P. R. China.
Peichuan YangInstitute of Orthopaedics, Tianjin Hospital, Tianjin University (Tianjin Hospital), Tianjin, 300211, P. R. China.
Yan LiInstitute of Orthopaedics, Tianjin Hospital, Tianjin University (Tianjin Hospital), Tianjin, 300211, P. R. China.
Yiyang LiInstitute of Orthopaedics, Tianjin Hospital, Tianjin University (Tianjin Hospital), Tianjin, 300211, P. R. China.
Liyun ZhouInstitute of Orthopaedics, Tianjin Hospital, Tianjin University (Tianjin Hospital), Tianjin, 300211, P. R. China.
Jiahui ShenInstitute of Orthopaedics, Tianjin Hospital, Tianjin University (Tianjin Hospital), Tianjin, 300211, P. R. China.
Xinlong MaInstitute of Orthopaedics, Tianjin Hospital, Tianjin University (Tianjin Hospital), Tianjin, 300211, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To summarize the influence of microstructure on performance of triply-periodic minimal surface (TPMS) bone scaffolds. Methods: The relevant literature on the microstructure of TPMS bone scaffolds both domestically and internationally in recent years was widely reviewed, and the research progress in the imfluence of microstructure on the performance of bone scaffolds was summarized. Results: The microstructure characteristics of TPMS bone scaffolds, such as pore shape, porosity, pore size, curvature, specific surface area, and tortuosity, exert a profound influence on bone scaffold performance. By finely adjusting the above parameters, it becomes feasible to substantially optimize the structural mechanical characteristics of the scaffold, thereby effectively preempting the occurrence of stress shielding phenomena. Concurrently, the manipulation of these parameters can also optimize the scaffold's biological performance, facilitating cell adhesion, proliferation, and growth, while facilitating the ingrowth and permeation of bone tissue. Ultimately, the ideal bone fusion results will obtain. Conclusion: The microstructure significantly and substantially influences the performance of TPMS bone scaffolds. By deeply exploring the characteristics of these microstructure effects on the performance of bone scaffolds, the design of bone scaffolds can be further optimized to better match specific implantation regions.

Indexed as

Tissue EngineeringTissue ScaffoldsBone and BonesPorositybone scaffoldmicrostructurepropertyTriply-periodic minimal surface

Identifiers

PMID37848329
PMCPMC10581883

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.