SynthesisBMJ open2023

Comparisons of procedural characteristics and clinical outcomes between SMARTTOUCH SURROUNDFLOW catheter and other catheters for atrial fibrillation radiofrequency catheter ablation: a systematic literature review.

Jianyong Li, Guifang Zhou, Xinzhong Li, Senlin Huang, Hairuo Lin, Shaopeng Lin, Liang Tan, Wendong Chen, Xiaobo Huang, Yuegang Wang

Open access · goldAbstract readSystematic ReviewMeta-Analysis
In one paragraph

Synthesis in BMJ open, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 72% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

Jianyong Li *Department of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China.
Guifang Zhou *Department of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China.
Xinzhong Li *Department of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China.
Senlin Huang *Department of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China.
Hairuo Lin *Department of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China.
Shaopeng Lin *Department of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China.
Liang TanChangsha Normin Health Technology Ltd, Changsha, China.
Wendong ChenNormin Health Consulting Ltd, Mississauga, Ontario, Canada.
Xiaobo HuangDepartment of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China chw47922@163.com.ORCID 0000-0001-9031-0923
Yuegang WangDepartment of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China.
Nanfang Hospital · CNUniversity of Toronto · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSMARTTOUCH SURROUNDFLOW (STSF) catheter is the new generation of SMARTTOUCH (ST) catheter with an upgraded irrigation system for radiofrequency catheter ablation (RFCA) in patients with atrial fibrillation (AF).

methodsThis systematic literature review searched the major English and Chinese bibliographic databases from 2016 to 2022 for any original clinical studies assessing the STSF catheter for RFCA in AF patients. Meta-analysis with a random effects model was used for evidence synthesis.

resultsPooled outcomes from 19 included studies indicated that STSF catheter was associated with a significantly shorter procedure time (weighted mean difference (WMD): -17.4 min, p<0.001), shorter ablation time (WMD: -6.6 min, p<0.001) and lower catheter irrigation fluid volume (WMD: -492.7 mL, p<0.001) than ST catheter. Pooled outcomes from four included studies with paroxysmal AF patients reported that using the STSF catheter for RFCA was associated with a significantly shorter ablation time (WMD: -5.7 min, p<0.001) and a lower risk of 1-year postablation arrhythmia recurrence (rate ratio: 0.504, p<0.001) than the SURROUNDFLOW (SF) catheter. Significant reductions in procedure time and ablation time associated with the STSF catheter were also reported in the other four studies using non-ST/SF catheters as the control. Overall complications of STSF catheter and control catheters were comparable.

conclusionsUsing the STSF catheter was superior to using the ST catheter to conduct RFCA for AF by significantly reducing procedure time, ablation time, fluoroscopy time and irrigation fluid volume. The superiority of the STSF catheter over the SF catheter and other non-ST/SF catheters for RFCA needs further confirmation.

Indexed as

Atrial FibrillationCatheter AblationCathetersHumansRecurrenceTime FactorsTreatment Outcomecardiac surgerycardiologysystematic review

Identifiers

PMID37848300
PMCPMC10582897
OpenAlexW4387702100

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.