Evidence map›Paper›PMID 37847495›Full record

ArticleExperimental physiology2024

MyoLoop: Design, development and validation of a standalone bioreactor for pathophysiological electromechanical in vitro cardiac studies.

Fotios G Pitoulis, Jacob J Smith, Blanca Pamias-Lopez, Pieter P de Tombe, Danika Hayman, Cesare M Terracciano

Open access · diamondAbstract read
In one paragraph

Article in Experimental physiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
3.2field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 10 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Cracking the Endothelial Calcium (CaInternational journal of molecular sciences · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 3 countries.

Fotios G PitoulisNational Heart & Lung Institute, Imperial College London, London, UK.ORCID 0000-0001-9814-9046
Jacob J SmithNational Heart & Lung Institute, Imperial College London, London, UK.ORCID 0009-0001-0656-745X
Blanca Pamias-LopezNational Heart & Lung Institute, Imperial College London, London, UK.ORCID 0009-0000-8381-7005
Pieter P de TombeDepartment of Physiology and Biophysics, University of Illinois at Chicago, Chicago, Illinois, USA.ORCID 0000-0003-3178-0233
Danika HaymanNational Heart & Lung Institute, Imperial College London, London, UK.
Cesare M TerraccianoNational Heart & Lung Institute, Imperial College London, London, UK.ORCID 0000-0003-2761-0696
Imperial College London · GBCentre National de la Recherche Scientifique · FR

Funding

British Heart Foundation FS/18/37/33642
6 · The paper itself

Abstract

Mechanical load is one of the main determinants of cardiac structure and function. Mechanical load is studied in vitro using cardiac preparations together with loading protocols (e.g., auxotonic, isometric). However, such studies are often limited by reductionist models and poorly simulated mechanical load profiles. This hinders the physiological relevance of findings. Living myocardial slices have been used to study load in vitro. Living myocardial slices (LMS) are 300-μm-thick intact organotypic preparations obtained from explanted animal or human hearts. They have preserved cellular populations and the functional, structural, metabolic and molecular profile of the tissue from which they are prepared. Using a three-element Windkessel (3EWK) model we previously showed that LMSs can be cultured while performing cardiac work loops with different preload and afterload. Under such conditions, LMSs remodel as a function of the mechanical load applied to them (physiological load, pressure or volume overload). These studies were conducted in commercially available length actuators that had to be extensively modified for culture experiments. In this paper, we demonstrate the design, development and validation of a novel device, MyoLoop. MyoLoop is a bioreactor that can pace, thermoregulate, acquire and process data, and chronically load LMSs and other cardiac tissues in vitro. In MyoLoop, load is parametrised using a 3EWK model, which can be used to recreate physiological and pathological work loops and the remodelling response to these. We believe MyoLoop is the next frontier in basic cardiovascular research enabling reductionist but physiologically relevant in vitro mechanical studies.

Indexed as

BioreactorsHeartAnimalsHumansMyocardiumResearch Designcardiac cycleelectromechanical stimulationin vitro cultureliving myocardial slicesmechanical loadMyoLoop

Identifiers

PMID37847495
PMCPMC10988681
OpenAlexW4387691884

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked