Evidence map›Paper›PMID 37846427›Full record

ReviewAdvances in ophthalmology practice and research

The theory of critical flicker fusion frequency and its application in cataracts.

Guangcan Xu, Junxia Fu, Haolan Qi, Linyu Li, Wenqian Chen, Yi Gao, Tianju Ma, Zi Ye, Zhaohui Li

Open access · goldAbstract readReview
In one paragraph

Review in Advances in ophthalmology practice and research. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Trichromatic critical flicker frequency as potential visual test in cataract and macula disease patients.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2024
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Guangcan XuSchool of Medicine, Nankai University, Tianjin, China.
Junxia FuDepartment of Ophthalmology, Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Haolan QiSchool of Medicine, Nankai University, Tianjin, China.
Linyu LiSchool of Medicine, Nankai University, Tianjin, China.
Wenqian ChenDepartment of Ophthalmology, The Third Medical Center, The Chinese People's Liberation Army General Hospital, Beijing, China.
Yi GaoDepartment of Ophthalmology, The Third Medical Center, The Chinese People's Liberation Army General Hospital, Beijing, China.
Tianju MaDepartment of Ophthalmology, The Third Medical Center, The Chinese People's Liberation Army General Hospital, Beijing, China.
Zi YeDepartment of Ophthalmology, The Third Medical Center, The Chinese People's Liberation Army General Hospital, Beijing, China.
Zhaohui LiSchool of Medicine, Nankai University, Tianjin, China.
Chinese People's Liberation Army · CNNankai University · CNShanghai Jiao Tong University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Due to media opacity, it is usually difficult to accurately evaluate the postoperative visual acuity in cataracts patients. As a small and portable tool, the critical flicker fusion frequency (CFF) device reflects the temporal resolution of visual function and has been widely used in clinical research. However, poor understanding of the technique and equipment limitations have restricted its clinical application in China. Main text: There was a decrease in the CFF value in various ophthalmic diseases, indicating that the CFF is sensitive to detect visual functional changes. A number of studies have shown that the CFF test can accurately distinguish patients with simple cataracts from those with cataracts combined with fundus disease, and, as a visual test, it can more accurately predict postoperative visual acuity without being affected by media opacity. This study comprehensive reviews the basic principles of CFF and its application in ophthalmology, especially in cataracts. Conclusions: As one of the tools for dynamic visual function detection, the CFF test could help doctors to assess the possible presence of fundus disease in cataracts patients, especially in eyes with dense cataracts, and more precisely provide a reasonable visual prognosis than other available visual tests.

Indexed as

CataractsCritical flicker fusion frequencyReview

Identifiers

PMID37846427
PMCPMC10577820
OpenAlexW4307155257

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.