ArticleAdvances in ophthalmology practice and research
Patient reported outcomes after implementation of an enhanced depth of focus intraocular lens with low postoperative myopia.
Article in Advances in ophthalmology practice and research. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 6 citations in OpenAlex.
- Functional Design Analysis of Two Current Extended-Depth-of-Focus Intraocular Lenses.Translational vision science & technology · 2024Article
- Visual, Refractive, Functional, and Patient Satisfaction Outcomes After Implantation of a New Extended Depth-of-Focus Intraocular Lens.Clinical ophthalmology (Auckland, N.Z.) · 2024Article
- Comparative Evaluation of Visual Performance and Patient Satisfaction following Cataract Surgery: A Retrospective Analysis of an Extended Depth-of-Focus Intraocular Lens and a Diffractive Multifocal Lens with Extended Depth of Focus.Journal of clinical medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Enhanced depth-of- focus intraocular lenses (EDOF IOL) have filled the gap between monofocal and multifocal intraocular implants with optical qualities of monofocal lenses and usually minor dysphotopsias typical for multifocal lenses. The purpose of this study was to evaluate visual outcomes after bilateral implantation of a new EDOF IOL in patients with requirements for perfect near and intermediate vision. Methods: The study included 15 patients (29 eyes as one was amblyopic) with bilateral implantation of LUXSMART EDOF IOL (Bausch & Lomb) with a targeted myopia (between -0.25 and -0.50D) in both eyes. Monocular corrected and uncorrected visual acuity for far, intermediate and near as well as refractive outcomes were evaluated at 1, 3, 6 and 12 months after the surgery. Additionally, binocular visual acuity, contrast sensitivity and defocus curve were measured at the final follow-up visit. At 12 months' visit patients completed a questionnaire evaluating patient satisfaction, spectacle independence and presence of dysphotopsias. Results: Binocular uncorrected visual acuities at 12 month's visit were 0.13 ± 0.16, 0.06 ± 0.08, 0.07 ± 0.09 and 0.15 ± 0.09 logMAR for far distance, 80 cm, 66 cm and 40 cm respectively. Corrected binocular visual acuities at 12 months were 0.00 ± 0.00, 0.05 ± 0.07, 0.05 ± 0.06, 0.13 ± 0.16 respectively for distance, 80 cm, 66 cm and 40 cm. Automated refraction spherical equivalent at 12 months' visit stood at -0.70 ± 0.48D, which was 0.46D less than calculated biometric target, however spherical equivalent of subjective refraction at 12 months equaled -0.49 ± 0.46D, which was closer to preoperative biometric target. Defocus curve had gentle shape without peaks typical for monofocal IOLs. Binocular contrast sensitivity results were superior to average results for that age group and equaled 1.78 ± 0.16 logMAR without correction and 1.81 ± 0.13 logMAR with correction. Spectacle independence for near and intermediate distances was achieved in all patients and for far distance in 73.3% of patients. Burdensome dysphotopsias were not reported in any case. Conclusions: EDOF IOLs targeted bilaterally at low myopia can provide excellent near and intermediate visual acuity and independence of any optical correction in majority of cases. This approach can be used in selected patients who are focused on stationary activities.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.