Evidence map›Paper›PMID 37842204›Full record

ArticleIEEE transactions on radiation and plasma medical sciences2023

Inter-pass motion correction for whole-body dynamic PET and parametric imaging.

Xueqi Guo, Jing Wu, Ming-Kai Chen, Qiong Liu, John A Onofrey, Darko Pucar, Yulei Pang, David Pigg, Michael E Casey, Nicha C Dvornek and 1 more

Abstract read
In one paragraph

Article in IEEE transactions on radiation and plasma medical sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. TAI-GAN: Temporally and Anatomically Informed GAN for Early-to-Late Frame Conversion in Dynamic Cardiac PET Motion Correction.Simulation and synthesis in medical imaging : ... International Workshop, SASHIMI ..., held in conjunction with MICCAI ..., proceedings. SASHIMI (Workshop) · 2023
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Xueqi GuoDepartment of Biomedical Engineering, Yale University, New Haven, CT, 06511, USA.
Jing WuDepartment of Biomedical Engineering, Yale University, New Haven, CT, 06511, USA, and the Center for Advanced Quantum Studies and Department of Physics, Beijing Normal University, Beijing, China.
Ming-Kai ChenDepartment of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06511, USA.
Qiong LiuDepartment of Biomedical Engineering, Yale University, New Haven, CT, 06511, USA.
John A OnofreyDepartment of Biomedical Engineering, the Department of Radiology and Biomedical Imaging, and the Department of Urology, Yale University, New Haven, CT, 06511, USA.
Darko PucarDepartment of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06511, USA.
Yulei PangDepartment of Biomedical Engineering, Yale University, New Haven, CT, 06511, USA, and Southern Connecticut State University, New Haven, CT, 06515, USA.
David PiggSiemens Medical Solutions USA, Inc., Knoxville, TN, 37932, USA.
Michael E CaseySiemens Medical Solutions USA, Inc., Knoxville, TN, 37932, USA.
Nicha C DvornekDepartment of Biomedical Engineering and the Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06511, USA.
Chi LiuDepartment of Biomedical Engineering and the Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06511, USA.

Funding

Yale Clinical and Translational Science Award (U Component)UL1TR001863 · NCATS · YALE UNIVERSITY · PI John H. Krystal, LUCILA OHNO-MACHADO · 2016 to 2026
$102.9M
Personalized Task-Based Respiratory Motion Correction for Low-Dose PET/CTR01CA224140 · NCI · YALE UNIVERSITY · PI LIU, CHI, SPOTTISWOODE, BRUCE SHAWN · 2018 to 2022
$3.1M
NCATS NIH HHS UL1 TR001863NCI NIH HHS R01 CA224140
6 · The paper itself

Abstract

Whole-body dynamic FDG-PET imaging through continuous-bed-motion (CBM) mode multi-pass acquisition protocol is a promising metabolism measurement. However, inter-pass misalignment originating from body movement could degrade parametric quantification. We aim to apply a non-rigid registration method for inter-pass motion correction in whole-body dynamic PET. 27 subjects underwent a 90-min whole-body FDG CBM PET scan on a Biograph mCT (Siemens Healthineers), acquiring 9 over-the-heart single-bed passes and subsequently 19 CBM passes (frames). The inter-pass motion correction was executed using non-rigid image registration with multi-resolution, B-spline free-form deformations. The parametric images were then generated by Patlak analysis. The overlaid Patlak slope

Indexed as

Inter-pass motion correctionnon-rigid registrationparametric imagingwhole-body dynamic PET

Identifiers

PMID37842204
PMCPMC10569406

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.