Evidence map›Paper›PMID 37842133›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2020

Super-Resolution in Digital Breast Tomosynthesis: Limitations of the Conventional System Design and Strategies for Optimization.

Raymond J Acciavatti, Trevor L Vent, Bruno Barufaldi, E Paul Wileyto, Peter B Noël, Andrew D A Maidment

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Signal-to-Noise Ratio and Contrast-to-Noise Ratio Measurements for Next Generation Tomosynthesis.Proceedings of SPIE--the International Society for Optical Engineering · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Raymond J AcciavattiUniversity of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
Trevor L VentUniversity of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
Bruno BarufaldiUniversity of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
E Paul WileytoUniversity of Pennsylvania, Department of Epidemiology, Biostatistics, & Informatics, 423 Guardian Drive, Philadelphia, PA 19104.
Peter B NoëlUniversity of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
Andrew D A MaidmentUniversity of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
California University of Pennsylvania · US

Funding

High Performance, Quantitative Breast PET Scanner Integrated With TomosynthesisR01CA196528 · NCI · UNIVERSITY OF PENNSYLVANIA · PI ANDREW DOUGLAS ARNOLD MAIDMENT, Suleman Surti · 2016 to 2026
$5.9M
NCI NIH HHS R01 CA196528
6 · The paper itself

Abstract

Our previous work explored the use of super-resolution as a way to improve the visibility of calcifications in digital breast tomosynthesis. This paper demonstrates that there are anisotropies in super-resolution throughout the reconstruction, and investigates new motion paths for the x-ray tube to suppress these anisotropies. We used a theoretical model of a sinusoidal test object to demonstrate the existence of the anisotropies. In addition, high-frequency test objects were simulated with virtual clinical trial (VCT) software developed for breast imaging. The simulated objects include a lead bar pattern phantom as well as punctate calcifications in a breast-like background. In a conventional acquisition geometry in which the source motion is directed laterally, we found that super-resolution is not achievable if the frequency is oriented in the perpendicular direction (posteroanteriorly). Also, there are positions, corresponding to various slices above the breast support, at which super-resolution is inherently not achievable. The existence of these anisotropies was validated with VCT simulations. At locations predicted by theoretical modeling, the bar pattern phantom showed aliasing, and the spacing between individual calcifications was not properly resolved. To show that super-resolution can be optimized by re-designing the acquisition geometry, we applied our theoretical model to the analysis of new motion paths for the x-ray tube; specifically, motions with more degrees of freedom and with more rapid pulsing (submillimeter spacing) between source positions. These two strategies can be used in combination to suppress the anisotropies in super-resolution.

Indexed as

Anthropomorphic PhantomCalcificationsDigital Breast TomosynthesisFourier TransformImage QualityImage ReconstructionSuper-ResolutionVirtual Clinical Trials

Identifiers

PMID37842133
PMCPMC10573083
OpenAlexW3026682203

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked