Evidence map›Paper›PMID 37841369›Full record

ArticleOSA continuum2021

Flexible and directional fibre optic ultrasound transmitters using photostable dyes.

Richard J Colchester, Callum D Little, Erwin J Alles, Adrien E Desjardins

Abstract read
In one paragraph

Article in OSA continuum, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Richard J ColchesterDepartment of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, WC1E 6BT, UK.ORCID https://orcid.org/0000-0001-8657-0546
Callum D LittleWellcome/ESPRC Centre for Interventional and Surgical Sciences, 43-45 Foley Street, London, W1W 7TY, UK.
Erwin J AllesDepartment of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, WC1E 6BT, UK.ORCID https://orcid.org/0000-0002-1658-4421
Adrien E DesjardinsDepartment of Medical Physics and Biomedical Engineering, University College London, Gower Street, London, WC1E 6BT, UK.

Funding

Wellcome Trust
6 · The paper itself

Abstract

All-optical ultrasound transducers are well-suited for use in imaging during minimally invasive surgical procedures. This requires highly miniaturised and flexible devices. Here we present optical ultrasound transmitters for imaging applications based on modified optical fibre distal tips which allow for larger transmitter element sizes, whilst maintaining small diameter proximal optical fibre. Three optical ultrasound transmitter configurations were compared; a 400 µm core optical fibre, a 200 µm core optical fibre with a 400 µm core optical fibre distal tip, and a 200 µm core optical fibre with a 400 µm core capillary distal tip. All the transmitters used a polydimethylsiloxane-dye composite material for ultrasound generation. The material comprised a photostable infra-red absorbing dye to provide optical absorption for the ultrasound transduction. The generated ultrasound beam profile for the three transmitters was compared, demonstrating similar results, with lateral beam widths <1.7 mm at a depth of 10 mm. The composite material demonstrates a promising alternative to previously reported materials, generating ultrasound pressures exceeding 2 MPa, with corresponding bandwidths

Identifiers

PMID37841369
PMCPMC10575603

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.