Evidence map›Paper›PMID 37841046›Full record

ArticleEuropean heart journal. Case reports2023

Tailored pre-procedural management and four-clip trans-catheter edge-to-edge repair procedure to efficiently treat torrential tricuspid regurgitation: a case report.

Julien Dreyfus, Ariel Nakache, Mohammed Nejjari

Open access · goldAbstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Julien DreyfusCardiology Department, Centre Cardiologique du Nord, 32-36 Rue des Moulins Gémeaux, Saint-Denis 93200, France.ORCID https://orcid.org/0000-0003-1338-3007
Ariel NakacheCardiology Department, Centre Cardiologique du Nord, 32-36 Rue des Moulins Gémeaux, Saint-Denis 93200, France.
Mohammed NejjariCardiology Department, Centre Cardiologique du Nord, 32-36 Rue des Moulins Gémeaux, Saint-Denis 93200, France.ORCID https://orcid.org/0000-0003-1096-1537
Centre Cardiologique du Nord · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The use of trans-catheter treatment for tricuspid regurgitation (TR) is currently increasing, especially trans-catheter edge-to-edge repair (TEER). However, patients with very large coaptation gaps are usually considered not eligible for this treatment. Case summary: We present the case of an 87-year-old man with symptomatic [New York Heart Association (NYHA) functional Class IV, right-sided heart failure signs] isolated torrential TR due to chronic atrial fibrillation who was initially considered not eligible for a tricuspid valve (TV) TEER because of a very large coaptation gap. A leadless pacemaker was implanted, and the patient received high doses of intravenous diuretics at home during 2 months. After heart team discussion, he was then considered suitable for a TEER procedure. A 'zipping' technique was performed, with the implantation of four TriClip devices, based on the anatomy of the TV and guided by fluoroscopy and bi- and tri-dimensional trans-oesophageal echocardiography, allowing an excellent procedural result (mild TR and mean TV gradient = 1 mmHg). At 6 months, TR was still mild, the patient reported a remarkable improvement (NYHA I, no heart failure signs), and 6-min walk test increased from 260 to 375 m. Discussion: This case underscores the need for heart valve centres with dedicated and experienced teams and networks of care to adequately manage patients with severe TR from pre-procedural choice of cardiac pacing type and optimization of diuretic therapy to customized interventions with appropriate number and location of clips according to the anatomy of the valve and the mechanism of TR, guided by high-quality bi- and tri-dimensional echocardiography.

Indexed as

Case reportManagementPercutaneous valve repairTricuspid regurgitation

Identifiers

PMID37841046
PMCPMC10568525
OpenAlexW4387207009

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.