Evidence map›Paper›PMID 37838723›Full record

ArticleScientific reports2023

The quality monitoring of paracetamol medicament using a noninvasive microwave sensor.

Youness Zaarour, Fatimazahrae El Arroud, Hafid Griguer, Rafiq El Alami, Mohammed El Kohen, Wiam Salhi, Abdessamad Faik, M'hamed Drissi

Abstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Youness ZaarourMicrowave Energy Sensing (MSE), DICE-University of Mohammed VI Polytechnic, 43152, Benguerir, Morocco. youness.zaarour@um6p.ma.
Fatimazahrae El ArroudMicrowave Energy Sensing (MSE), DICE-University of Mohammed VI Polytechnic, 43152, Benguerir, Morocco.
Hafid GriguerMicrowave Energy Sensing (MSE), DICE-University of Mohammed VI Polytechnic, 43152, Benguerir, Morocco.
Rafiq El AlamiMicrowave Energy Sensing (MSE), DICE-University of Mohammed VI Polytechnic, 43152, Benguerir, Morocco.
Mohammed El KohenMicrowave Energy Sensing (MSE), DICE-University of Mohammed VI Polytechnic, 43152, Benguerir, Morocco.
Wiam SalhiMicrowave Energy Sensing (MSE), DICE-University of Mohammed VI Polytechnic, 43152, Benguerir, Morocco.
Abdessamad FaikLaboratory for Inorganic Materiels for Sustainable Energy Technologies (LIMSET), University of Mohammed VI Polytechnic, 43152, Benguerir, Morocco.
M'hamed DrissiMicrowave Energy Sensing (MSE), DICE-University of Mohammed VI Polytechnic, 43152, Benguerir, Morocco.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Environmental conditions, including temperature, humidity, and light, can impact the quality of drugs. Microwave-based approaches offer a fast and cost-effective way to detect quality variations, providing an alternative to traditional techniques in the pharmaceutical and cosmetic industries. This article proposes the use of a microwave sensor for monitoring the quality of pharmaceutical drugs at distinct temperature levels. A small planar sensor based on three hexagonal split ring resonators (TH-SRR) is fabricated. The design is manufactured on an FR-4 dielectric substrate. The sensor is tested on a 1000 mg paracetamol tablet, at temperatures ranging from 40 to 80 [Formula: see text]C. The Variation in the permittivity that characterizes product degradation is translated into a shift in the frequency of the scattering matrix elements. To validate the microwave approach, drug quality is examined with the laser-induced breakdown spectroscopy (LIBS) technique, an optical emission laser used for both qualitative and quantitative investigations of elements contained in a sample. The existing elements are classified using the National Institute of Standards and Technology (NIST) database and categorized according to their spectral line wavelengths. The experiments show the presence of optimal wavelength values for carbon (C), hydrogen (H), nitrogen (N), and oxygen (O) at 247.92 nm, 656.49 nm, 244.23 nm, and 777.48 nm, respectively. The microwave experimental results show a shift frequency of approximately 1 MHz on average when the tablet is heated at 80 [Formula: see text]C for 15 min. Meanwhile, the LIBS measurement shows a remarkable shift in terms of intensity of approximately 8884 and 812 for carbon and hydrogen, respectively. Understanding how paracetamol dries under high temperatures and improving the process settings of the microwave sensor are investigated and assessed in this work.

Identifiers

PMID37838723
PMCPMC10576772

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.