ArticleGeneral thoracic and cardiovascular surgery2024
Performance of the ENSEAL X1 Curved Jaw Tissue Sealer in thoracic procedures in a Japanese cohort: a case series report.
Article in General thoracic and cardiovascular surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Contributing factors to heparin resistance during cardiopulmonary bypass.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAdvanced vessel sealing electrosurgical systems have been widely adopted for grasping, cutting, and sealing vessels. Data remain sparse with regard to its use in thoracic procedures. Thus, a prospective case series, utilizing the ENSEAL X1 Curved Jaw Tissue Sealer (X1CJ) and its companion energy source, the Generator 11 (GEN11), in thoracic procedures was performed in a Japanese cohort.
methodsSubjects were recruited at two Japanese surgical sites. The primary endpoint of this post-market study was the achievement of hemostasis (≤ Grade 3) for each thoracic vessel transection. Performance endpoints included scores for tasks completed with X1CJ (adhesiolysis, lymphatics or tissue bundles divided, tissue grasping, tissue cutting, or tissue dissection); hemostasis grading vessel transected; additional products required to achieve hemostasis for Grade 4 vessel transections. Safety was evaluated by evaluating device-related adverse events. All endpoint data were summarized.
resultsForty subjects (50.0% female) of Asian ethnicity with a mean age of 67.6 ± 11.3 years underwent a lung resection. Estimated mean blood loss was 39.5 mL. Hemostasis was achieved in 97.5% of vessel transections. Thirty-seven vessel sealings resulted in a hemostatic Grade 1 (92.5%). All surgeons reported satisfaction/neutral in terms of tissue grasping (100.0%) while most reported satisfaction/neutral with tissue cutting (95.7%). One device-related serious adverse event was reported (2.5%), a chylothorax requiring an extension of hospitalization. There was no post-operative bleeding or deaths reported during the study period.
conclusionThe X1CJ demonstrated safe and effective performance without any reports of significant intra-operative or post-operative hemorrhage in thoracic vessel sealing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.