ArticleSensors (Basel, Switzerland)2023
A Front-End Circuit for Two-Wire Connected Resistive Sensors with a Wire-Resistance Compensation.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 17 citations in OpenAlex.
- A Multiplexable Op-Amp Interface for Accurate Readout of Remote Resistive Sensors.Sensors (Basel, Switzerland) · 2026Article
- Intelligent Transducer for Temperature Measurement with Two-Wire or Three-Wire Platinum RTD.Sensors (Basel, Switzerland) · 2024Article
- Two Proposals of a Simple Analog Conditioning Circuit for Remote Resistive Sensors with a Three-Wire Connection.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this article, a novel front-end circuit for remote two-wire resistive sensors that is insensitive to the wire resistances is proposed and experimentally characterized. The circuit relies on an OpAmp-based current source with a square-wave excitation, two twin diodes in the feedback path, and a low-pass filter at the output. Using such a circuit topology, the output is a DC voltage proportional to the sensor resistance and independent of the wire resistances. A prototype was built measuring resistances that correspond to a Pt100 thermal sensor and with different values of wire resistance. The experimental results show that the output voltage is almost insensitive to both the wire resistances and their mismatch, with a relative error (with respect to the case with null parasitic resistance) in the range of 0.01-0.03% Full-Scale Span (FSS). In addition, the proposed circuit shows a remarkable linearity (around 0.01% FSS), and again this is independent of the presence and also of the mismatch of the wire resistances.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.