ArticleSensors (Basel, Switzerland)2023
A Study on the Harmonic Distortion of Seismic-Grade Sigma-Delta MEMS Accelerometers Using a Multiple Degree-of-Freedom Model.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Harmonic distortion is one of the dominant factors limiting the overall signal-to-noise and distortion ratio of seismic-grade sigma-delta MEMS accelerometers. This study investigates harmonic distortion based on the multiple degree-of-freedom model (MDM) established in our previous study. The main advantage of using an MDM is that the effect of finger flexibility on harmonic distortion is considered. Initially, the nonlinear relationship between the input acceleration and output signal is derived using the MDM. Then, harmonic distortion is simulated and described in terms of the nonlinear input-output relationship. It is found that finger flexibility and parasitic capacitance mismatch both decrease harmonic distortion. Finally, the experimental testing of harmonic distortion is implemented. By reducing the finger length to realize a higher stiffness and compensating for the parasitic capacitance mismatch, the total harmonic distortion decreases from -66.8 dB to -86.9 dB.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.