Evidence map›Paper›PMID 37836925›Full record

ArticleSensors (Basel, Switzerland)2023

A Segmental 2D Readout Board Manufactured in Printed Circuit Board Technology for Gas Electron Multiplier Detectors.

Michał Babij, Piotr Bielówka, Szymon Gburek, Karol Malecha

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Michał BabijDepartment of Microsystems, Faculty of Electronics, Photonics and Microsystems, Wrocław University of Science and Technology, wyb. S. Wyspiańskiego 27, 50-370 Wrocław, Poland.ORCID 0000-0001-9859-422X
Piotr BielówkaDepartment of Microsystems, Faculty of Electronics, Photonics and Microsystems, Wrocław University of Science and Technology, wyb. S. Wyspiańskiego 27, 50-370 Wrocław, Poland.ORCID 0000-0002-5333-1968
Szymon GburekCentrum Badań Kosmicznych PAN (CBK PAN), ul. Bartycka 18a, 00-716 Warszawa, Poland.ORCID 0000-0002-6587-6332
Karol MalechaDepartment of Microsystems, Faculty of Electronics, Photonics and Microsystems, Wrocław University of Science and Technology, wyb. S. Wyspiańskiego 27, 50-370 Wrocław, Poland.ORCID 0000-0002-2240-0326

Funding

Ministry of Science and Higher Education DWD/4/5/2020; DIR.ZPSW.62.77.2020
6 · The paper itself

Abstract

The Gas Electron Multiplier (GEM) was introduced by Fabio Sauli in 1997. This technology is broadly used in current and planned High-Energy Physics (HEP) experiments. One of the key components of these detectors is a readout board, which collects charges amplified by GEM foils and transfers them to readout electronics. The commonly used Cartesian XY readout boards are manufactured from the same type of polyamide film used to produce the GEM foils. The manufacturing process utilizes a deep polyimide etching, similar to the Micro Chemical Vias (MCV) etching process, which is protected by patent. The material prepared in this way is glued onto a rigid substrate and mounted in a detector. The production process was developed at CERN, and the technology has been commercialized to a small extent. Consequently, only a few research centers have the ability to make dedicated readout strips readouts. GEM detectors are characterized by a segmented structure that allows the separation of an electron-multiplying structure from a readout. This feature enables the implementation of a new type of charge reading system without the need to interfere with the GEM foil system. A new approach is proposed to simplify production and reduce the costs of GEM detector readout boards. It is based on the concept of segmental readout structures that are manufactured in standard Printed Circuit Board (PCB) technology. The interconnectors and mountings are located on the back of the bottom, so it is possible to place the readout electronics behind the readout plate. The boards are designed in such a way that they can be panelized into a readout with a more extensive active area. The margin between PCBs is minimalized to approximately 200 µm, which is less than 1% of the 70 × 70 mm

Indexed as

Gas Electron Multiplier (GEM) detectorMicro Pattern Gas Detector (MPGD)radiation sensorsX-ray