Evidence map›Paper›PMID 37836921›Full record

ArticleSensors (Basel, Switzerland)2023

The Accuracy and Absolute Reliability of a Knee Surgery Assistance System Based on ArUco-Type Sensors.

Vicente J León-Muñoz, Fernando Santonja-Medina, Francisco Lajara-Marco, Alonso J Lisón-Almagro, Jesús Jiménez-Olivares, Carmelo Marín-Martínez, Salvador Amor-Jiménez, Elena Galián-Muñoz, Mirian López-López, Joaquín Moya-Angeler

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 1 country.

Vicente J León-MuñozDepartment of Orthopaedic Surgery and Traumatology, Hospital General Universitario Reina Sofía, 30003 Murcia, Spain.ORCID 0000-0002-0429-2579
Fernando Santonja-MedinaDepartment of Orthopaedic Surgery and Traumatology, Hospital Clínico Universitario Virgen de la Arrixaca, 30120 Murcia, Spain.
Francisco Lajara-MarcoDepartment of Orthopaedic Surgery and Traumatology, Hospital General Universitario Reina Sofía, 30003 Murcia, Spain.
Alonso J Lisón-AlmagroDepartment of Orthopaedic Surgery and Traumatology, Hospital General Universitario Reina Sofía, 30003 Murcia, Spain.
Jesús Jiménez-OlivaresDepartment of Orthopaedic Surgery and Traumatology, Hospital Vega Baja, 03314 Orihuela, Spain.ORCID 0000-0003-4831-9830
Carmelo Marín-MartínezDepartment of Orthopaedic Surgery and Traumatology, Hospital General Universitario Reina Sofía, 30003 Murcia, Spain.ORCID 0009-0003-0551-0341
Salvador Amor-JiménezDepartment of Orthopaedic Surgery and Traumatology, Hospital General Universitario Reina Sofía, 30003 Murcia, Spain.
Elena Galián-MuñozDepartment of Orthopaedic Surgery and Traumatology, Hospital General Universitario Reina Sofía, 30003 Murcia, Spain.
Mirian López-LópezDepartment of Information Technologies, Subdirección General de Tecnologías de la Información, Servicio Murciano de Salud, 30100 Murcia, Spain.
Joaquín Moya-AngelerDepartment of Orthopaedic Surgery and Traumatology, Hospital General Universitario Reina Sofía, 30003 Murcia, Spain.ORCID 0000-0002-3520-2521
Hospital Reina Sofía de Murcia · ESHospital Universitario Virgen de la Arrixaca · ESHospital Vega Baja · ESServicio Murciano de Salud · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recent advances allow the use of Augmented Reality (AR) for many medical procedures. AR via optical navigators to aid various knee surgery techniques (e.g., femoral and tibial osteotomies, ligament reconstructions or menisci transplants) is becoming increasingly frequent. Accuracy in these procedures is essential, but evaluations of this technology still need to be made. Our study aimed to evaluate the system's accuracy using an in vitro protocol. We hypothesised that the system's accuracy was equal to or less than 1 mm and 1° for distance and angular measurements, respectively. Our research was an in vitro laboratory with a 316 L steel model. Absolute reliability was assessed according to the Hopkins criteria by seven independent evaluators. Each observer measured the thirty palpation points and the trademarks to acquire direct angular measurements on three occasions separated by at least two weeks. The system's accuracy in assessing distances had a mean error of 1.203 mm and an uncertainty of 2.062, and for the angular values, a mean error of 0.778° and an uncertainty of 1.438. The intraclass correlation coefficient was for all intra-observer and inter-observers, almost perfect or perfect. The mean error for the distance's determination was statistically larger than 1 mm (1.203 mm) but with a trivial effect size. The mean error assessing angular values was statistically less than 1°. Our results are similar to those published by other authors in accuracy analyses of AR systems.

Indexed as

Augmented RealitySurgery, Computer-AssistedFemurOsteotomyReproducibility of Resultsaccuracyangleaugmented reality (AR)distancekneeorthopaedics

Identifiers

PMID37836921
PMCPMC10575457
OpenAlexW4387059752

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.